Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Permit Number - TC-MDP-1125-00728
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/24/2025 | Residential Building | APPROVED | |||
| 11/21/2025 | Fire New Construction | NOT REQUIRED | |||
| 12/05/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/21/2025 | Residential Engineering | REQUIRES RESUBMIT | Permit: TC-MDP-1125-00728 Location: 2153 W WAGON WHEELS DR Review Date: 11/21/2025 Site Engineering Comments: 1. Per the City of Tucson Inclusive Home Design Ordinance: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf, all new dwellings and units have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway, sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402, 403, & 404 of the ADA Accessibility Standards: https://www.access-board.gov/ada/chapter/ch04/ 2. After reviewing the final plat for Ironwood Hills, it appears there are discrepancies regarding property line measurements. Revise accordingly If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 11/28/2025 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston, Planner PROJECT: TC-MDP-1125-00728 2153 W Wagon Wheels Dr., Tucson, AZ 85745 Model SFR (1st Review) TRANSMITTAL DATE: 11/28/2025 This site is located within the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Please correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. The site plan provided is insufficient for a zoning review. For reference, here is the link for the template and requirements of a site plan: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example . Please provide the following: a. North arrow b. Corrected property dimensions as those on the site plan do not match the recorded plat found at https://maps-and-records.tucsonaz.gov/subdivisions/details/1637 c. Correct zoning (R-1, not R-2) and zoning of abutting properties d. Label the alleyway to the south and provide its width e. The floor plan and elevations (north, south, east and west) of the model home for staff to verify with the approved model plan (TC-MDP-0325-00203) f. Show a dimension from the center line of the cul-de-sac to edge of pavement or curb and a dimension from edge of pavement or curb to the property line. The paving plan for the Ironwood Hills District may be found at https://maps-and-records.tucsonaz.gov/construction-plans/details/I-69-014 , plan I-69-014_010.tif 2. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov . |
||
| 11/20/2025 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 12/05/2025 | ROW Engineering Review | REVIEW COMPLETED | ROW PERMIT REQUIRED PRIOR TO WORKING IN THE ROW. WAGON WHEELS DR IS UNDER PAVEMENT MORATORIUM, NEW PAVEMENT CUTS SHOULD NOT EXCEED 4' WIDTH. |
||
| 11/26/2025 | TW New Development Review Fast | REVIEW COMPLETED | Based on the information provided, Tucson Water New Area Development (NAD) has no objections , or comments, on the proposed project. There is an existing 6" CA water main under PN Number PN 039-1973 is the main to tie the proposed new residence. If any new other domestic water, or irrigation are needed to serve this proposed development, please contact Tucson Water’s New Services Section by calling 520-791-5164 or by sending an email to TW_Common@tucsonaz.gov. The above comments are based on the limited preliminary information provided by the applicant. |