Review Date Reviewer's Name Type of Review Description Status Comments
12/02/2025 Fire New Construction NOT REQUIRED
N/A Bldg Permits - Post Review Express PENDING ASSIGNMENT
N/A Design Review PENDING ASSIGNMENT
N/A ROW Engineering Review PENDING ASSIGNMENT
12/01/2025 Residential Building REQUIRES RESUBMIT Please show connection from proposed unit to existing HCS.
11/26/2025 Residential Engineering REQUIRES RESUBMIT Permit: TC-MDP-1125-00718
Location: 813 E DRACHMAN ST Unit: UNIT 1
Review Date: 11/26/2025
Site Engineering Comments:
1. Parcel 123151290 at 813 E Drachman ST is entirely located within the City of Tucson Mabel Street floodplain and will require the submission of a floodplain use permit with Elevation Certificate for the proposed SFR Unit 1. For this process, the proposed SFR will be given a required finished floor elevation (FFE) which will be required for floodplain compliance.
2. To submit for the FPU permit, go to the sub records of permit TC-MDP-1125-00718 within the TDC account associated with the permit.
3. It was found that the base flood elevation (BFE) for the proposed Unit 1 is 2415.60 FT NAV88. This will require a minimum finished floor elevation of 2416.60 FT NAV88
4. For the submission of the FPU permit and resubmission of the Model Permit, please submit the construction plans with a general note that states “SFR to be built to a Finished Floor Elevation of 2416.60”
5. Site Engineering will be unable to approve permit TC-MDP-1125-00718 until the associated FPU permit is approved and the elevation certificate process is begun.
6. Per the City of Tucson Inclusive Home Design Ordinance: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf, all new dwellings and units have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway, sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402, 403, & 404 of the ADA Accessibility Standards: https://www.access-board.gov/ada/chapter/ch04/
If you have any questions or concerns, please contact
Marco Contreras
Marco.contreras@tucsonaz.gov
12/02/2025 Residential Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: Georgia Pennington
PDSD Zoning Review Section

PROJECT:
TC-MDP-1125-00718
813 E Drachman St Unit 1


TRANSMITTAL: 12/2/25

COMMENTS:

This site is located in the NR-2 zone (UDC 5.10.3). A single-family residence (SFR) is a permitted use in this zone (Table NR-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10.

1. Per UDC 5.10, prior to zoning approval an NPZ review and approval is required.

2. The lot coverage should include all buildings, storage, vehicle use area (improved or unimproved), as a percentage of the total lot area. Include both units into lot coverage calculation. The maximum lot coverage permitted is 70%. See UDC 6.4.3 for Rules for Measurement.

3. Per UDC Table 6.3-2.A, the maximum permitted residential density is 15 units/acre. Provide a density calculation to the general notes to demonstrate compliance with this standard.

4. Add zoning classification of adjacent properties including across right of way.

If you have questions about this transmittal, please contact me at Georgia.pennington@tucsonaz.gov
11/25/2025 PDSD Application Completeness Express REVIEW COMPLETED
11/26/2025 TW New Development Review Fast REVIEW COMPLETED Based on the information provided, Tucson Water New Area Development (NAD) has no objection or additional comments on the proposed development. Parcel 123151290 is currently served by an existing 3/4" water meter off the 8" C.A. PN-001-1949. If this project is planned to be tied to the 8" C.A. PN-049-1970. If any new domestic water services are needed to serve this proposed development, please contact Tucson Water’s New Services Section by calling 520-791-5164 or by emailing TW_Common@tucsonaz.gov.