Permit Number: TC-MDP-1125-00717
Parcel: 112064210

Address:
2406 E COPPER ST

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1

Permit Number - TC-MDP-1125-00717
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/02/2025 Fire New Construction NOT REQUIRED
12/11/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/04/2025 Residential Building REQUIRES RESUBMIT Requires resubmit.

Please note:

Each dwelling should have a separate clear 3-foot fire separation distance, R302 amended. Therefore, either dwelling within a 6-foot space between dwellings requires one-hour fire resistance rating (no openings) including roof projections. Relocate the ADU from the 6-foot separation or provide details for compliance with IBC Table 721.1(2).

If you have any questions please reach out to me jorge.ruiz@tucsonaz.gov
12/01/2025 Residential Engineering REQUIRES RESUBMIT Permit: TC-MDP-1125-00717
Location: 2406 E COPPER ST
Review Date: 12/1/2025
Site Engineering Comments:
1. Per the City of Tucson Inclusive Home Design Ordinance: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf, all new dwellings and units have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway, sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402, 403, & 404 of the ADA Accessibility Standards: https://www.access-board.gov/ada/chapter/ch04/
2. Provide reference to the plat map used/shown on the cover sheet. In reference to the final plat for “Sudano Catalina View addition,” It appears to be some discrepancies regarding the property line dimensions and this final plat was found from the Pima County Recorder’s office. Revise accordingly.
3. In reference to the final plat for “Sudano Catalina View addition,” there exists a 5-foot easement that runs along the West property line. It is required that this easement is shown and called out on the plan set.
If you have any questions or concerns, please contact
Marco Contreras
Marco.contreras@tucsonaz.gov
12/10/2025 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Roxanne Johnston
Planner

PROJECT: TC-RES-1125-00717
2406 E Copper St., Tucson, AZ 85719
Model ADU (1st Review)

TRANSMITTAL DATE: 12/10/2025

This site is located within the R-2 Zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. Per the City of Tucson Inclusive Home Design Ordinance -https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf , all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk.” Draw, dimension and label an access route from the driveway (or apron ), sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402-404 of the ADA Accessibility Standards https://www.access-board.gov/ada/chapter/ch04/ . See the Technical Standards Manual (TSM) 7-01.4.3 for specifications, including slope and composition materials – https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-10261 Please add a comment and show the pathway demonstrating that the ADU will meet ADA per the above codes.

2. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov .
11/28/2025 PDSD Application Completeness Express REVIEW COMPLETED
12/08/2025 ROW Engineering Review REVIEW COMPLETED ROW permit required prior to working in the ROW
12/11/2025 TW New Development Review Fast REVIEW COMPLETED Based on the information provided, Tucson Water has New Area Development (NAD) no objections to the proposed development. Based on the plumbing plan provided, the 768 SF casita shows a total of six (6) plumbing fixtures served by the proposed meter, as follows: one (1) water closet, one (1) lavatory, one (1) clothes washer, one (1) kitchen sink, and one (1) shower, which is counted as two (2) fixtures due to separate hot and cold water supplies. Assuming the other two casitas (988 SF and 1,092 SF) have the same number and type of fixtures, and further assuming that no exterior hose bibbs or dedicated irrigation connections are provided, the three units together would total eighteen (18) fixtures. While the IPC allows a maximum of 20 fixtures on a 5/8" water meter, Tucson Water highly recommends upsizing the domestic water meter to 3/4" to provide adequate capacity and accommodate potential future demand. This project is being fed by an existing 5/8 meter 22129561. If any new domestic water, are needed to serve this proposed development, please contact Tucson Water’s New Services Section by calling 520-791-5164 or by sending an email to TW_Common@tucsonaz.gov.
The above comments are based on the limited preliminary information provided by the applicant.