| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/26/2024 | Residential Building | APPROVED | |||
| 01/06/2025 | Site Engineering | APPROVED | |||
| 12/20/2024 | Fire New Construction | NOT REQUIRED | |||
| 01/09/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/09/2025 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-MDP-1124-01279 237 E 25th St. – C-1 New Duplex (1st Review) TRANSMITTAL DATE: January 9, 2025 Provided a detailed comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. This site is located in the C-1 zone (UDC 4.7.20). A duplex is a permitted use in this zone (Table 4.8-4). 1. The lot coverage calculation is not correct. Per UDC Article 6.4.3.B.3.b Vehicular use areas, measured within the outside edges of any area allocated to vehicle use, whether improved or unimproved are included in the lot coverage. This includes any area necessary to access the parking area shown on the plan. 2. Per UDC Table 6.3-2.A the minimum perimeter yard setback from a res use to res zone is 10’-0” or ¾ the height of the structure’s wall facing each interior property line, greater of the two. Based on a wall height of less than 13’-4” the required perimeter yard setback from the proposed duplex to the west property line is 10’-0”, proposed setback is 6’-0”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 12/19/2024 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 01/07/2025 | ROW Engineering Review | REVIEW COMPLETED |