Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2
Permit Number - TC-MDP-1123-01834
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/11/2024 | Fire New Construction | NOT REQUIRED | |||
| 09/25/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/12/2024 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-MDP-1123-01834 (1603 S VAN BUREN AV TUCSON, 85711) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC), 2018 International Plumbing Code (IPC) 1. There is an open Lot Division permit associated with this parcel. TD-DIV-0724-00061 (5708 E 26TH ST TUCSON, AZ 85711). This lot division needs to be approved and issued prior to this permit being approved. (May also require an address update to the permit since 5708 E 26th ST no longer exists) 2. If you plan on doing the lot split for the two different addresses, then each building requires an independent sewer connection from the building to the Pima County sewer connection. 2018 IPC 701.3. 3. The building sewer line, for units 3 and 4, is shown crossing into the neighboring parcel. There is no record of a Pima County sewer line in this location. You cannot cross property boundaries to share a sewer connection. 2018 IPC 701.3. 4. The water and sewer lines crossing the new property boundary will require a registered easement. This easement and the proposed location of the water and sewer lines must be shown on the Lot Division documents for TD-DIV-0724-00061. 5. Provide elevation measurements for Next Upstream Manhole cover and Finished Floor Elevation. Provide Backwater valve protection as/if required. 6. Backwater valve protection: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/building-code/2018_-_irc_amendments.pdf Section P3008.1 Where required. Where the finish floor elevation is less than 12 inches above the elevation of the next upstream manhole cover in the sewer, a backwater valve shall be installed in the building drain or branch of the building drain serving that floor. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 09/11/2024 | ROW Engineering Review | REQUIRES RESUBMIT | Site plan: Show existing and proposed Right-of-Way features. Provide distances and dimensions for the following: 1. Driveway (PAG SD 206) Max. width for residential driveway is 20’ 2.Sidewalk (PAG SD 200) 6’ for arterial/collector roadways. 3.Road Type: ARTERIAL SCENIC, Show 30’ scenic route setback 4.For collector/arterial roadways, show onsite vehicle maneuverability. *Unused existing curb cuts shall be closed. |
||
| 09/25/2024 | Site Engineering | REQUIRES RESUBMIT | A development package is required and must be approved before this building permit can be approved. Mike Ortiz michael.ortiz@tucsonaz.gov |
||
| 09/24/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-MDP-1123-01834 1603 S VAN BUREN AV. – R-2 Multifamily (1st Review) TRANSMITTAL DATE: September 24, 2024 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-2 zone (UDC 4.7.9). Multifamily is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. 1. The proposed multifamily project requires a Development Package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The Administrative Manual can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes-and-Plans/Zoning-Code#section-1. This DP is a separate submittal form the building plans. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 09/10/2024 | PDSD Application Completeness Express | REVIEW COMPLETED | This permit only covers Units 1 & 2. Each building requires a separate residential model permit and a separate submittal is required for units 3 & 4. |