Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-MDP-1123-01820
Parcel: 136130880

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL PERMIT - SUBDIVISION v.1

Permit Number - TC-MDP-1123-01820
Review Name: SITE FROM MODEL PERMIT - SUBDIVISION v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/27/2023 Site Engineering APPROVED
11/29/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/24/2023 Fire New Construction REQUIRES RESUBMIT Clarify the proximity of the existing fire hydrant to the proposed drive. Provide clear space in accordance with 2018 IFC, 507.5.4 and 507.5.5.
Questions: patricia.shelton@tucsonaz.gov / 520.837.7082
11/21/2023 Residential Building REQUIRES RESUBMIT Permit Review TC-MDP-1123-01820 (2621 S OAKENSHIELD WY TUCSON, AZ 85730)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC).

1. Provide elevation measurements for both the Next Upstream Manhole and Finished Floor Elevation. Provide Backwater valve protection as/if required.
Backwater valve protection:
https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/building-code/2018_-_irc_amendments.pdf Section P3008.1

2. Provide permitting or other evidence that the electric and gas lines exist in the back alleyway or provide utility permits to install these lines.

3. There is an existing fire hydrant that appears to be in the center of the driveway’s exit into the public way. Provide Fire, Water and/or ROW permits for moving or working around this obstacle.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
11/27/2023 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-MDP-1123-01820
2621 S. Oakenshield Wy. - O-3
New SFR (1st Review)

TRANSMITTAL DATE: November 27, 2023

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the O-3 zone (UDC 4.7.15). A single-family residence is a permitted use in this zone (Table 4.8-3).

1. It does not appear that the curb and sidewalk are shown correctly. Per paving plan I-73-029 found at: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-73-029, the sidewalk is located 1’ from the west property line. Provide a dimension from the center line of Oakenshield to the face of curb and from the face of curb to the west property line.

2. Per UDC Article 6.4.5.C.1.a For single-family and duplex development , the minimum required front street perimeter yard is 20 feet measured from the street property line. A Design Development Option (DDO) must be submitted and approved to reduce the front street perimeter yard setback to 19-0”. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov.

3. Per UDC Article 6.4.5.C.1.b where a lot abuts more than one street, the owner chooses which street lot line is the front lot line. From other than the front lot line, the street perimeter yard is ten feet, as measured from the street property line. A Design Development Option (DDO) must be submitted and approved to reduce the side street perimeter yard setback to 6’-8”. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
11/29/2023 Zoning Modifications - DDO REQUIRES RESUBMIT If perimeter yard requirements as described within the Site Zoning review cannot reasonably be met, a Design Development Option (DDO) is required to reduce the front street and side street perimeter yards.

The DDO application and requirements can be found here: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/2019_ddo_for_setback_and_height_udc.pdf. Please note that incomplete or poorly prepared applications will be returned for corrections. Submit the DDO application under existing permit number TC-MDP-1123-01820.

Contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951 should you have questions about the DDO process.
11/21/2023 PDSD Application Completeness Express REVIEW COMPLETED