Permit Review Detail
Review Status: In Review
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Permit Number - TC-MDP-1026-00913
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/06/2026 | Residential Building | APPROVED | |||
| 11/09/2026 | Residential Engineering | APPROVED | |||
| 11/05/2026 | Fire New Construction | NOT REQUIRED | |||
| N/A | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| N/A | ROW Engineering Review | PENDING ASSIGNMENT | |||
| 11/12/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Claire Leighou, Planner PROJECT: TC-MDP-1026-00913 5823 S VINE AV Middle Housing Triplex (1st Review) TRANSMITTAL DATE: 11/12/26 This site is located in the R-2 zone (UDC 4.7.9). Middle housing projects up to four units are permitted in this zone (Table 4.8.4) subject to Use Specific Standards 4.9.7.B.6, .8, .9 & .11 - .14. Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. Comment 1: Thank you for including the required trees on the site plan. Per UDC 7.6.8.A, all new single family, middle housing, and accessory dwelling unit development requires the following landscaping in addition to trees: Vegetative groundcover is required within the front yard setback per the calculation below. ((X Linear feet of Street Frontage) - (Y Curb cut width)) x (5 Foot Depth) = Z Square Feet of vegetative groundcover. Please include this calculation and label the square footage on the plans. Additional details on landscaping requirements may be found in the zoning code here: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-6131 The list of allowable trees/groundcover plants may be found here: https://www.azwater.gov/sites/default/files/media/TAMA2015LWUPL_0.pdf Comment 2: Please add a note to the attached Overall Layout plan that it is for reference only. Comment 3: Per UDC table 7.4.4-1, all new single family and developments with 2-5 units require one parking space per unit. Required parking may be met with on-street parking or waived if the site is within a quarter-mile walking distance of an “All Ages and Abilities Bikeway” as defined by the Department of Transportation and Mobility or a public transit route (UDC 4.9.7.B.12). Please add a note to the main site plan page stating this project is choosing to include no parking on site due to the proximity to a bus stop and/or bike route. The eligibility area in which this site is located is the low-stress bicycle network: Drexel Road shared use path, per Middle Housing GIS website, linked here: https://middle-housing-cotgis.hub.arcgis.com/pages/Parking-Waiver-Eligibility. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code If you have any questions about this transmittal, please contact Claire Leighou at claire.leighou@tucsonaz.gov. Thank you! |
||
| 11/05/2026 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 11/17/2026 | TW New Development Review Fast | REVIEW COMPLETED | Tucson Water has no objection to the proposed development. Three (3) 5/8" water meters are approved for this project. The existing 3" PVC water main located in the alley is a potential connection point for the proposed water services. Please contact Tucson Water New Services when ready to proceed with the water meter installations. The property must remain as a single parcel and cannot be subdivided after construction. |