Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-MDP-1025-00649
Parcel: 120073640

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1

Permit Number - TC-MDP-1025-00649
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/22/2025 Residential Building APPROVED
10/09/2025 Fire New Construction NOT REQUIRED
10/23/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/13/2025 Residential Engineering REQUIRES RESUBMIT Permit: TC-MDP-1025-00649
Location: 404 W PRESIDENT ST
Review Date: 10/13/2025
Site Engineering Comments:
1. The provided North arrow appears to be incorrect in relation to the orientation of the provided site plan, revise accordingly.
2. Per the City of Tucson Inclusive Home Design Ordinance: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf, all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway, sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402, 403, & 404 of the ADA Accessibility Standards: https://www.access-board.gov/ada/chapter/ch04/
3. Show and call out the accessible route to connect to the street frontage along W President ST.
4. There is a drawing index, but the plans are a single sheet, revise accordingly.
5. Provide a call out for any fence/wall that will separate this site from other parcels, so that they function independently from one another.

If you have any questions or concerns, please contact
Marco Contreras
Marco.contreras@tucsonaz.gov
10/23/2025 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL
FROM: Roxanne Johnston
Planner
PROJECT: TC-RES-0925-04748
404 W President St, Tucson, AZ 85714
Model SFR (1st Review)

TRANSMITTAL DATE: 10/23/2025

This site is located within the R-2 Zone (UDC 4.7.9). A single-family and duplex residence are permitted uses in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

1. W. President St. does not run north to south. Please correctly orient the north arrow.
2. S. Lundy Ave. is located east of the subject lot. Please add S. Lundy Ave to the plot plan.
3. A Drawing Index is called out on the site plan, but the sheets are not included. Please supply building elevations.
4. Additional comments may be forthcoming on the next review based on responses to Zoning and/or other PDSD reviewer comments.

For questions regarding Zoning comments, please contact me at: Roxanne.Johnston@tucsonaz.gov.
10/17/2025 ROW Engineering Review REQUIRES RESUBMIT Review Red line notes on plan. Call out Sidewalk connection to existing ADA ramp, and Close unused Curb Cuts to be closed off and Curb Restored.
10/08/2025 PDSD Application Completeness Express REVIEW COMPLETED