Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Permit Number - TC-MDP-1025-00649
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/22/2025 | Residential Building | APPROVED | |||
| 10/09/2025 | Fire New Construction | NOT REQUIRED | |||
| 10/23/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/13/2025 | Residential Engineering | REQUIRES RESUBMIT | Permit: TC-MDP-1025-00649 Location: 404 W PRESIDENT ST Review Date: 10/13/2025 Site Engineering Comments: 1. The provided North arrow appears to be incorrect in relation to the orientation of the provided site plan, revise accordingly. 2. Per the City of Tucson Inclusive Home Design Ordinance: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf, all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway, sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402, 403, & 404 of the ADA Accessibility Standards: https://www.access-board.gov/ada/chapter/ch04/ 3. Show and call out the accessible route to connect to the street frontage along W President ST. 4. There is a drawing index, but the plans are a single sheet, revise accordingly. 5. Provide a call out for any fence/wall that will separate this site from other parcels, so that they function independently from one another. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 10/23/2025 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston Planner PROJECT: TC-RES-0925-04748 404 W President St, Tucson, AZ 85714 Model SFR (1st Review) TRANSMITTAL DATE: 10/23/2025 This site is located within the R-2 Zone (UDC 4.7.9). A single-family and duplex residence are permitted uses in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10. 1. W. President St. does not run north to south. Please correctly orient the north arrow. 2. S. Lundy Ave. is located east of the subject lot. Please add S. Lundy Ave to the plot plan. 3. A Drawing Index is called out on the site plan, but the sheets are not included. Please supply building elevations. 4. Additional comments may be forthcoming on the next review based on responses to Zoning and/or other PDSD reviewer comments. For questions regarding Zoning comments, please contact me at: Roxanne.Johnston@tucsonaz.gov. |
||
| 10/17/2025 | ROW Engineering Review | REQUIRES RESUBMIT | Review Red line notes on plan. Call out Sidewalk connection to existing ADA ramp, and Close unused Curb Cuts to be closed off and Curb Restored. | ||
| 10/08/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |