Permit Number: TC-MDP-1023-01665
Parcel: 11507023A

Address:
19 E ELM ST

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL PERMIT - PRODUCTION v.1

Permit Number - TC-MDP-1023-01665
Review Name: SITE FROM MODEL PERMIT - PRODUCTION v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/15/2023 Residential Building APPROVED
11/09/2023 Site Engineering APPROVED
11/16/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/07/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review Section

PROJECT: TC-MDP-1023-01665
19 E. Elm St. - R-2
New SFR (1st Review)

TRANSMITTAL DATE: November 7, 2023

Provide a detailed comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal.

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10.

1. The north setback shown for the north property line is not correct. Per UDC Table 6.3-2.A R-2 zone, Res Use to a Nonres zone the required setback is 10’-0” or ¾” (H) Height of the exterior wall as measured from design grade to the highest point of the wall, greater of the two measurements. Based on a wall height of 13’-3” the required setback is 10’-0”. Remove the setback lines as the required setbacks shown to the property line is not correct.

2. The perimeter yard setback from the proposed residence to the west property is not correct and should be show as 10’-0” or ¾” (H) Height of the exterior wall as measured from design grade to the highest point of the wall, greater of the two measurements. Based on a wall height of 9’-6” the required perimeter yard setback from the proposed SFR to the west property lines is 10’-0”, proposed perimeter yard setback is 8.69’ (UDC Table 6.3-2.A). A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
11/07/2023 PDSD Application Completeness Express REVIEW COMPLETED
11/16/2023 Site Landscape REVIEW COMPLETED