Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-MDP-1023-01665
Parcel: 11507023A

Address:
19 E ELM ST

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL PERMIT - PRODUCTION v.4

Permit Number - TC-MDP-1023-01665
Review Name: SITE FROM MODEL PERMIT - PRODUCTION v.4
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/17/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/10/2024 Residential Building REQUIRES RESUBMIT Permit Review TC-MDP-1023-01665 (19 E ELM ST TUCSON, AZ 85705)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC).

>>> The following comment was not addressed.
1. Provide elevation measurements for Next Upstream Manhole and Finished Floor Elevation on the site plan. Provide Backwater valve protection as/if required. Backwater valve protection: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/building-code/2018_-_irc_amendments.pdf Section P3008.1 Where required. Where the finish floor elevation is less than 12 inches above the elevation of the next upstream manhole cover in the sewer, a backwater valve shall be installed in the building drain or branch of the building drain serving that floor.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
01/11/2024 Site Engineering REQUIRES RESUBMIT This project is within a regulated floodplain and requires a Floodplain Use Permit (FUP.)
Please start a new FUP at our permit application web page:
https://tdc-online.tucsonaz.gov/#/home
NOTE: Documentation of a cost estimate from your contractor will be required if this project involves any reconstruction, repair, rehabilitation, structurally connected addition, or other improvement of an existing structure (including TIs and solar). Construction of separate builds/new structures does not require a cost estimate to be provided. Construction of new buildings require elevation one foot above the base flood elevation, which may require that the foundation of the building be raised as much as two feet above the existing elevation onsite. Storage buildings with no utilities may be wet floodproofed using flood vents. For all new construction buildings, two elevation certificates must be filled out by a registered land surveyor and submitted to the City, one before the foundation is poured and one after construction is completed.
Instructions:
1. Navigate into the current project in the “My Work” tab. Within the permit, navigate to the “Sub-Records” tab and click “Apply” on the Floodplain Use Permit Sub-Record
2. Locations -> Confirm the location is accurate to the project. Click “Next”
3. Type -> Fill in the “Square Feet” and “Valuation” boxes with the project area and a contractor-provided cost estimate (See note above: for new structures, input 0). Click “Next”
4. Contacts -> Confirm contacts and add any additional contacts if applicable. Click “Next”
5. More Info -> This will be filled in by the engineer assigned to your case, Click “Next”
6. Attachments -> Please attach the project plan, supporting documentation for the cost estimate (if applicable), and a drainage/hydrology report (if applicable). Click “Next”
7. Signature -> Read the statement and type your name. Sign your name below (You may Enable Type Signature to have the software sign for you.) Click “Next”
8. Review and Submit -> Review all information to ensure accuracy. Click “Submit”
Contact Lianne Evans at lianne.evans@tucsonaz.gov or Stephen Blood at Stephen.Blood@tucsonaz.gov if you have any questions about the FUP.
01/11/2024 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review Section

PROJECT: TC-MDP-1023-01665
19 E. Elm St. - R-2
New SFR (3rd Review)

TRANSMITTAL DATE: January 11, 2024

Provide a detailed comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal.

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10.

1. Zoning can approve of this building permit until the Design Development Option (DDO) process is complete and approved. Once the process is completed, the site plan provided on the next submittal must reflect the reduced setbacks as approved per the DDO process.

If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov.

If you have any questions about this transmittal, please contact Nathan.Herrera@tucsonaz.gov.
01/09/2024 Zoning Modifications - DDO REQUIRES RESUBMIT The submitted plan set indicate that the required side (west) perimeter yard is proposed to be reduced from 10'-0" to 8'-8". However, the submitted DDO application indicates that a reduction of the required side (east) perimeter yard from 6'-4" to 5'-0" is requested. Clarify which perimeter yard is proposed to be reduced.

Contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951 if you have questions about my comments.
01/09/2024 PDSD Application Completeness Express REVIEW COMPLETED
01/17/2024 Site Landscape REVIEW COMPLETED