Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL PERMIT - SUBDIVISION v.1
Permit Number - TC-MDP-1023-01596
Review Name: SITE FROM MODEL PERMIT - SUBDIVISION v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/20/2023 | Site Engineering | APPROVED | |||
| 10/19/2023 | Site Landscape | APPROVED | |||
| 10/25/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/23/2023 | Residential Building | REQUIRES RESUBMIT | 1. A roof projection may not extend closer than 24” to the neighboring property line. Any part of a roof projection extending into the 3-foot fire separation distance from the property line requires not less than one-hour fire-resistive construction on the underside, R302.1 (City of Tucson Amended). The plans for TC-MDP-0823-01464 show a 1'-6" roof project. Provide revised roof projection plans when placing the ADU overhang into the fire separation distance or relocate the ADU with a greater setback. 2. Roof projections extending into the 3-foot fire separation distance to the neighboring property line require not less than one-hour fire-resistive construction on the underside, R302.1 (City of Tucson Amended). Provide revised roof projection plans when placing the ADU overhang into the fire separation distance or relocate the ADU with a greater setback. |
||
| 10/25/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: TC-MDP-1023-01596 7800 S CLAREMON AV Zoning R-2 ADU TRANSMITTAL DATE:October 25, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: Per UDC section 6.6.3.B.2 “In addition to parking required for the principal use , one parking space shall be provided for the accessory dwelling unit . The parking requirement may be satisfied with available on-street parking or waived if the site is within ¼ mile walking distance of a transit stop or an enhanced bike route as listed in the Bike Boulevard Master Plan. Parking provided is exempt from Section 7.6.4, Landscape Standards” Show the proposed parking. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
| 10/18/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |