Permit Number: TC-MDP-0924-01047
Parcel: 11006084A

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1

Permit Number - TC-MDP-0924-01047
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/04/2024 Site Zoning APPROVED
11/07/2024 Fire New Construction NOT REQUIRED
12/04/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/07/2024 Residential Building REQUIRES RESUBMIT Permit Review (4061 E MONTE VISTA DR TUCSON, AZ 85712)
TC-MDP-0924-01046
TC-MDP-0924-01047
TC-MDP-0924-01048
TC-MDP-1124-01282
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC).

Fire separation: The line used to determine fire separation distance is an imaginary line drawn between the two structures, typically centered between the two structures.

1. Roof projections extending into the 3-foot fire separation distance require not less than one-hour fire-resistive construction on the underside, R302.1 (City of Tucson Amended). The fire protected overhang may not extend closer than 24” from the line used to determine the fire separation distance.
2. Provide a note stating that any overhang extending into the fire separation distance shall be 1-hr fire rated on the underside. R302.1 (City of Tucson Amended).

3. The minimum distance between structures, with no fire rated wall assembly, is 6’ and a maximum 1’ overhang. The walls are shown with a 3’ 2” separation from the fire separation line (OK). The 2’ overhang extends closer than 24” from the fire separation line.

4. Show the roof projections, on the two sides closest to the other 2 buildings, extending no closer than 24” from the fire separation line. (Max overhang is approximately 12”).

Addressing:
5. You will need to file an address change request to have all the address and Unit numbers listed on the permit.
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/withdraws-and-extensions.pdf. On step #5, apply for change of address.

6. Resubmit updated plans to show/highlight the correct address and unit numbers covered under this permit.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
11/19/2024 Site Engineering REQUIRES RESUBMIT 1. A floodplain use permit with elevation certificate is required and must be approved before this building permit can be approved. Please provide the plans showing the FFE for the floodplain use permit, and please resubmit for this building permit.

Mike Ortiz
michael.ortiz@tucsonaz.gov
11/04/2024 PDSD Application Completeness Express REVIEW COMPLETED The plan submitted shows to be for Multiple duplexes. The location does not have units attached to the address and a pre issuance addressing condition has been placed on permit. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to verify and add the units. Note, an address change is required to determine what units this permit is for and to have both units added to this permit.
11/05/2024 ROW Engineering Review REVIEW COMPLETED ROW Engineering Review review completed under related DP# TD-DEV-0624-00172