Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL PERMIT - SUBDIVISION v.1
Permit Number - TC-MDP-0923-01558
Review Name: SITE FROM MODEL PERMIT - SUBDIVISION v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/28/2023 | Residential Building | NOT REQUIRED | |||
| 09/28/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/28/2023 | Site Engineering | REQUIRES RESUBMIT | This project is within a regulated floodplain and requires a Floodplain Use Permit (FUP.) Please start a new FUP at our permit application web page: https://tdc-online.tucsonaz.gov/#/home NOTE: Documentation of a cost estimate from your contractor will be required if this project involves any reconstruction, repair, rehabilitation, structurally connected addition, or other improvement of an existing structure (including TIs and solar). Construction of separate builds/new structures does not require a cost estimate to be provided. Construction of new buildings require elevation one foot above the base flood elevation, which may require that the foundation of the building be raised as much as two feet above the existing elevation onsite. Storage buildings with no utilities may be wet floodproofed using flood vents. For all new construction buildings, two elevation certificates must be filled out by a registered land surveyor and submitted to the City, one before the foundation is poured and one after construction is completed. Instructions: 1. Navigate into the current project in the “My Work” tab. Within the permit, navigate to the “Sub-Records” tab and click “Apply” on the Floodplain Use Permit Sub-Record 2. Locations -> Confirm the location is accurate to the project. Click “Next” 3. Type -> Fill in the “Square Feet” and “Valuation” boxes with the project area and a contractor-provided cost estimate (See note above: for new structures, input 0). Click “Next” 4. Contacts -> Confirm contacts and add any additional contacts if applicable. Click “Next” 5. More Info -> This will be filled in by the engineer assigned to your case, Click “Next” 6. Attachments -> Please attach the project plan, supporting documentation for the cost estimate (if applicable), and a drainage/hydrology report (if applicable). Click “Next” 7. Signature -> Read the statement and type your name. Sign your name below (You may Enable Type Signature to have the software sign for you.) Click “Next” 8. Review and Submit -> Review all information to ensure accuracy. Click “Submit” Contact Lianne Evans at lianne.evans@tucsonaz.gov or Stephen Blood at Stephen.Blood@tucsonaz.gov if you have any questions about the FUP. |
||
| 09/28/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-MDP-0923-02-1558 5621 E. Scarlett St. - R-1 New ADU (1st Review) TRANSMITTAL DATE: September 27, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, 8, & 9 and 6.6.3.aa 1. The lot coverage calculation is not correct and shall include all vehicle use areas, measured within the outside edges of any area allocated to vehicle use, whether improved or unimproved, UDC Article 6.4.3.B.3.b. 2. The setback to the east property line is not correct. Per UDC Article 6.4.5.C.1b Where a lot abuts more than one street, the owner chooses which street lot line is the front lot line. From other than the front lot line, the street perimeter yard is ten feet, as measured from the street property line. As Bright Ave is a named street, see the Mesa Village Estates final plat. The required street perimeter yard setback is 10’-0” to the east property line, proposed is not clear as no dimension was provided from the northeast corner of the proposed ADU. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. 3. The information listed under “MAXIMUM ACCESSORY DWELLING UNIT SQUARE FOOTAGE” is not correct. Review UDC Article 6.6.3.B.5 and provide the correct information. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 09/27/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |