Permit Number: TC-MDP-0923-01518
Parcel: 131061070

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL PERMIT - PRODUCTION v.1

Permit Number - TC-MDP-0923-01518
Review Name: SITE FROM MODEL PERMIT - PRODUCTION v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/05/2024 Site Zoning APPROVED
02/08/2024 Site Engineering NOT REQUIRED
02/13/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
02/13/2024 Residential Building REQUIRES RESUBMIT Permit Review TC-MDP-0923-01518 (1859 S MATH QUIZ DR TUCSON, AZ 85711)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC).

1. Template TC-MDP-0323-00812 approved plans do not include a 1-hour rated wall. Either use a different approved model template plan with the 1-hour rated wall or an approved revision to TC-MDP-0323-00812 before the site plan approval. Any structure built within the 3’ fire separation will require a 1 hr fire rated construction per R302.1 (City of Tucson Amended).
2. Provide elevation measurements for Next Upstream Manhole and Finished Floor Elevation. Provide Backwater valve protection as/if required.
Backwater valve protection:
https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/building-code/2018_-_irc_amendments.pdf Section P3008.1

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
02/05/2024 PDSD Application Completeness REVIEW COMPLETED