Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL PERMIT - SUBDIVISION v.1
Permit Number - TC-MDP-0923-01487
Review Name: SITE FROM MODEL PERMIT - SUBDIVISION v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/07/2023 | Site Engineering | APPROVED | |||
| 09/07/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/07/2023 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-MDP-0923-01487 (6657 E CALLE ALEGRIA Unit:UNIT B TUCSON, AZ 85715) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1. There is already an existing issued permit for the same scope of work for this address. We cannot have multiple active permits for the same scope of work. You will need to withdraw Permit: T21CM09764 (Duplex) if you wish to continue with this permit. https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/withdraws-and-extensions.pdf 2. Provide elevation measurements for Next Upstream Manhole and Finished Floor Elevation. Provide Backwater valve protection as required. Backwater valve protection: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/building-code/2018_-_irc_amendments.pdf Section P3008.1 Where required. Where the finish floor elevation is less than 12 inches above the elevation of the next upstream manhole cover in the sewer, a backwater valve shall be installed in the building drain or branch of the building drain serving that floor. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 09/07/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: TC-MDP-0923-01487 6657 E CALLE ALEGRIA Zoning R-3 TRANSMITTAL DATE:September 7, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: Please revise the setbacks as they are incorrect, The side setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Measured from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. The rear setback is the greater of ten (10) feet, or three-fourths (3/4) the height of the structure’s wall facing each interior property line. 2.COMMENT: As there are multiple roof heights, on the site plan show the height of each roof line with the setback dimensioned. Measured from design grade to the top of wall. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
| 09/06/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |