Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Permit Number - TC-MDP-0825-00442
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/02/2025 | Residential Building | APPROVED | |||
| 08/19/2025 | Fire New Construction | NOT REQUIRED | |||
| 09/05/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/02/2025 | Site Engineering | REQUIRES RESUBMIT | TC-MDP-0825-00442 702 W CALLE ADELANTO Site engineering comments are as follows: 1. Neither of the individual site plans for these two developments, TC-MDP-0825-00443 and TC-MDP-0825-00442, include a depiction of the common walk that runs between the Parking areas. If this walk is to be installed, it will need to be elevated to provide vertical separation from the PAAL [TSM 7-01.4.2]. It will also need to be located entirely on the eastern property, MDP-0825-00442, i.e. the parcel line cannot divide the walk. 2. Dimension the Parking area. 3. Include a North Arrow on the full site plan. Ryan Insalaco Engineering Associate ryan.insalaco@tucsonaz.gov Phone: (520) 837-5351 |
||
| 09/05/2025 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-MDP-0825-00442 702 W. Calle Adelanto Tucson, AZ 85705 Duplex SFR & ADU (1st Review) TRANSMITTAL DATE: 9/5/2025 This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6,.9, .10. Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: Site zoning is unable to approve this permit until the Design Development Option (DDO) has been approved. Please see below. 2. Comment: The following comments are related to an application for a Design Development Option (DDO) (UDC 3.11.1): This property has frontage along 3 streets (W. Calle Retama, N. 15th Ave., W. Calle Adelanto). UDC 6.4.5.C.1.b states “Where a lot abuts more than one street, the owner chooses which street lot line is the front lot line. From other than the front lot line, the street perimeter yard is 10’, as measured from the street property line”. The proposed setback along the East property line which fronts N. 15th Avenue is only 6’. The proposed reduced setback will require approval through the DDO application process. Please apply for your DDO as a zoning modification sub-record. For information on how to apply for sub-record, please visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf. For additional questions about the DDO process, please reach out to Georgia Pennington at Georgia.Pennington@tucsonaz.gov or Mark Castro at Mark.Castro@tucsonaz.gov. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 08/18/2025 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 09/05/2025 | ROW Engineering Review | REVIEW COMPLETED | Onsite Pedestrian access easement required for shared accessible route 12' Min. between driveways. |