Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Permit Number - TC-MDP-0824-00876
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/05/2024 | Residential Building | APPROVED | |||
08/23/2024 | Fire New Construction | NOT REQUIRED | |||
09/10/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
08/29/2024 | Historic | REQUIRES RESUBMIT | Property is designated as a contributor to the Historic Preservation Zone and requires review and approval. It appears that several items are missing from the submittal that are required for the historic review to take place. 1) inventory form of property 2) narrative consistent with 5.8 (https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/checklist_for_historic_design_review_-_general.pdf) 3) correct the Development Zone which is only the north side of 17th Street to Sameniego. Photos should be updated to only show buildings within the development zone. 4) resubmit the revised packet under the Historic sub record. Once we have a complete packet the project can be docketed. | ||
09/06/2024 | Site Engineering | REQUIRES RESUBMIT | Clarify the use of the existing rear structure (E) | ||
09/06/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-MDP-0824-00876 538 W 17TH ST., Unit #2 – HO-3 New ADU (1st Review) TRANSMITTAL DATE: September 6, 2024 This site is located in the HO-3 zone (UDC 4.7.12). A single-family residence (SFR) with an Accessory Dwelling Unit (ADU) is a permitted use in this zone (Table 4.8-3). See Use-Specific Standards 6.6.3. 1. Under the Building area you list “EXISTING COVERED AREA: 1,089 SF”, clarify if this is the existing dwelling or not. 2. Provide a setback dimension from the northwest corner and midpoint of the north wall of the proposed ADU to the north property line. 3. Based on aerial photos the covered porch shown attached to the rear of the existing residence was expanded some time after 2010. Zoning was not able to find approved permit documents for this expansion. Either provide copies of the approved permit documents or submit a separate permit for the expansion. Zoning will not be able to approve this permit until the porch expansion is addressed. COMMENTS: the following comments are relative to an application for Historic Review (UDC 5.8.8). The minimum setback is the greater of ten (10) feet, or three-fourth (3/4) the height of the structure’s wall facing each interior property line (Table 6.3-3.A). 1. Based on a wall height of 13’-6” the required perimeter yard setback from the proposed ADU to the north and east property line is 10’-2”. The north wall of the proposed ADU does not run parallel to the north property line and no setback was provided from the closest corner, northwest corner, or from midpoint of the north wall for the average distance to the north property line was not provide. Proposed distance from the northeast corner of the ADU is 4’-7”. Proposed setback from the proposed ADU to the east property line is 2’-0”. Historic application/requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Historic-Preservation. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
08/23/2024 | PDSD Application Completeness | REVIEW COMPLETED | |||
09/10/2024 | ROW Engineering Review | REVIEW COMPLETED | No Comments |