Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Permit Number - TC-MDP-0824-00871
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/23/2024 | Fire New Construction | NOT REQUIRED | |||
09/10/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
09/05/2024 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-MDP-0824-00862 (1339 E 8TH ST Unit:UNIT 2 TUCSON, AZ 85719) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC). 1. Provide elevation measurements for Next Upstream Manhole cover and Finished Floor Elevation. Provide Backwater valve protection as/if required. Backwater valve protection: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/building-code/2018_-_irc_amendments.pdf Section P3008.1 Where required. Where the finish floor elevation is less than 12 inches above the elevation of the next upstream manhole cover in the sewer, a backwater valve shall be installed in the building drain or branch of the building drain serving that floor. 2. Provide the size of the existing building sewer line that to verify code compliant capacity, P3005.4.2. 3. Provide the water pipe diameter between the meter and both shut off valves in compliance with P2903.7. A minimum 1” service pipe is required for supplying water to more than 9.5 fixture units. Show the size of the existing main water line. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
09/10/2024 | ROW Engineering Review | REQUIRES RESUBMIT | Review-- Driveway and Parking Access Concerns on Site plan. Then Re-upload. | ||
09/09/2024 | Site Engineering | REQUIRES RESUBMIT | The main building permit must be approved before the sleeping quarters can be approved. Mike Ortiz michael.ortiz@tucsonaz.gov |
||
09/06/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-MDP-0824-00871 1339 E 8TH ST. – R-2 ADU Model Plan Micro Unit – Sleeping quarters (1st Review) TRANSMITTAL DATE: September 6, 2024 This site is located in the NR-2 zone (UDC 5.10.3). A single-family residence (SFR) with an Accessory Dwelling Unit (ADU) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, 8, & 9 and 6.6.3. 1. Until permit TC-MDP-0824-00825 is approved by all review agencies Zoning cannot approve this plan. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
08/23/2024 | PDSD Application Completeness | REVIEW COMPLETED |