| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/14/2023 | Residential Building | APPROVED | |||
| 08/11/2023 | Site Engineering | NOT REQUIRED | |||
| 08/14/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/11/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-MDP-0823-01370 2023 E. 18th St. - R-2 New SFR (1st Review) TRANSMITTAL DATE: August 11, 2023 Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence w/ sleeping quarters is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9. 1. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Based on model plan TC-MDP-0723-01261, sheet A-2 elevations the only height dimensions provided are from finished floor therefore Zoning has added 6” to the 9’-0” height shown, 9’-6” to determine required perimeter yard setbacks. 9’-6” x 2/3 = 6’-4” required setback to the east and west property line. Propose setback is 5’-0”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. 2. Revise the setbacks listed to show the correct required setbacks. 3. The lot coverage calculation is not correct. Per UDC Article 6.4.3.C.1.a roofed areas, open on at least one side, which provide shelter to exterior areas, such as balconies, entrances, stoops, and terraces, provided they are not used for utilities, maintenance, laundry, storage, or motor vehicle parking. Remove the “COV’D ENTRY” from the calculation. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 08/10/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 08/10/2023 | Site Landscape | REVIEW COMPLETED |