| 09/14/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/11/2023 | Site Engineering | REQUIRES RESUBMIT | 1. During a recent floodplain audit, the City of Tucson determined that we must require a grading plan for all new build projects in the floodplain. A grading permit will be required for this development. Since both 1119 and 1115 E Fort Lowell are on the same parcel, they can be submitted under the same grading permit. The grading permit must be applied for under the development package application type on the TDC Online portal and must include an estimate for the cut and fill earthwork quantities for raising the building pads above the BFE. Lianne Evans lianne.evans@tucsonaz.gov |
||
| 09/06/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: TC-MDP-0723-01323 1119 E. Fort Lowell Rd. - O-3 New SFR (2nd Review) TRANSMITTAL DATE:September 6, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the O-3 zone (UDC 4.7.15). A single-family residence is a permitted use in this zone (Table 4.8-3). 1. The perimeter yard setbacks shown for the Side & Rear are not correct. Per UDC TABLE 6.3-3.A: DIMENSIONAL STANDARDS FOR THE O-1, O-2, & O-3 ZONES, O-3 Zone, Res Use to Res or Nonres Zone the required perimeter yard setback is 10' or ¾(H) = Height of the proposed exterior building wall, the greater of the two dimensions applies. Based on a wall height less than 13’-4” the required perimeter yard setbacks should be 10’-0”.A Design Development Option (DDO) must be submitted and approved to reduce the required setback, DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/planning-amp-zoning/2019_ddo_for_setback_and_height_udc.pdf . The completed application shall be submitted as a PDF under assigned permit number. If you have questions about the DDO application or process please contact Wyatt Berger at wyatt.berger@tucsonaz.gov or Georgia Pennington at georgia.pennington@tucsonaz.gov 2. As Fort Lowell Rd. is designated on the COT MS&R map as an Arterial clearly demonstrate that vehicles will be able to turn around on site and not have to back out onto Fort Lowell Rd right-or-way if all vehicle parking spaces are occupied. All vehicle maneuvering must be on site. 3. Remove SFR by separate permit from the site plan, Please provide approved lot split from COT, provide demolition permit for the structure. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
| 09/14/2023 | Zoning Modifications - DDO | REQUIRES RESUBMIT | DDO-23-73 is currently in progress. If the DDO is approved, upload a copy of the decision letter in addition to a revised plan set and a comment response letter. Contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951 if you have questions about the DDO process. |
||
| 09/06/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 09/11/2023 | ROW Engineering Review | REVIEW COMPLETED | TC-MDP-0823-01323 1119 E. Ft. Lowell Rd. Comments: 1. A curb-returned entrance as drawn on the “Title Sheet/ Site Plan,” cannot be constructed at this location due to an existing driveway apron/ curb cut for the adjacent property- 1125 E. Ft. Lowell Rd. 2. The “existing” driveway curb cut for this property (1119 E. Ft. Lowell Rd) appears to be up to code and can be utilized as an entrance to the property. David Stiffey DTM Project Coordinator David.Stiffey@tucsonaz.gov |