Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-MDP-0823-01323
Parcel: 11304345B

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL PERMIT - PRODUCTION v.1

Permit Number - TC-MDP-0823-01323
Review Name: SITE FROM MODEL PERMIT - PRODUCTION v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/21/2023 Residential Building APPROVED
08/22/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
08/21/2023 Site Engineering REQUIRES RESUBMIT 1. A floodplain use permit can only apply for a single building. A separate floodplain use permit will be required for this building.

Lianne Evans
lianne.evans@tucsonaz.gov
08/18/2023 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review

PROJECT: TC-MDP-0723-01323
1119 E. Fort Lowell Rd. - O-3
New SFR (1st Review)

TRANSMITTAL DATE: ‎August 18, 2023

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the O-3 zone (UDC 4.7.15). A single-family residence is a permitted use in this zone (Table 4.8-3).

1. The model plan permit number, T22-M0072 is currently in “VOID” status, clarify what model plan is going to be used.

2. The perimeter yard setbacks shown for the Side & Rear are not correct. Per UDC TABLE 6.3-3.A: DIMENSIONAL STANDARDS FOR THE O-1, O-2, & O-3 ZONES, O-3 Zone, Res Use to Res or Nonres Zone the required perimeter yard setback is 10' or ¾(H) = Height of the proposed exterior building wall, the greater of the two dimensions applies. Based on a wall height less than 13’-4” the required perimeter yard setbacks should be 10’-0”.

3. As Fort Lowell Rd. is designated on the COT MS&R map as an Arterial clearly demonstrate that vehicles will be able to turn around on site and not have to back out onto Fort Lowell Rd right-or-way if all vehicle parking spaces are occupied. All vehicle maneuvering must be on site.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov
08/17/2023 PDSD Application Completeness Express REVIEW COMPLETED
08/22/2023 Site Landscape REVIEW COMPLETED