Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Permit Number - TC-MDP-0726-00624
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/06/2026 | Residential Engineering | APPROVED | |||
| 08/06/2026 | Residential Zoning | APPROVED | |||
| 08/19/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/31/2026 | Addressing Validation | REQUIRES RESUBMIT | 1) Please update the address on the site plan to Bldg 2, Unit 2101 & 2102. | ||
| 08/04/2026 | Fire New Construction | REQUIRES RESUBMIT | Farthest point of building 2 is greater than the allowed 150 feet from closest point fire apparatus can get to. Per 2024 IFC 503.1.1 Exception 1 (1.1), this distance can be increased if building 2 is equipped throughout with with an approved automatic sprinkler system installed in accordance with 2024 IFC section 903.3.1.1, 903.3.1.2, or 903.3.1.3 Ryan P Johnson Tucson Fire Department Fire Plans Examiner email: Ryan.Johnson@Tucsonaz.gov |
||
| 08/19/2026 | ROW Engineering Review | REQUIRES RESUBMIT | DTM Review Comments - Refer to Redline comments on Plans Site plan: Show existing and proposed Right-of-Way features to include all Dimension and distances for work within ROW and Pavement, along with distances and dimensions for the following: 1. Driveway (PAG SD 206) Max. width for residential driveway 2.Sidewalk (PAG SD 200) Existing with Repairs to be made for any missing or damage panels along Frontage 3.Road Type: Local 4.For collector/arterial roadways, show onsite vehicle maneuverability. 5. Review DTM Chapter 25 for Driveway placement 6. Technical Standards Manual 10-01.4.3 Concrete driveway construction up to back of sidewalk (8' back edge of pavement) *Unused existing curb cuts shall be closed. Note and Review Update DTM Fees and review process for work within Right of Way. Note all Work within Right of Way will require Separate ROW - Development/Building permits per scope of work performed.. https://www.tucsonaz.gov/Departments/Transportation-Mobility/Permits-and-Codes-Section/Rate-and-Fee-Changes |
||
| 07/31/2026 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 08/03/2026 | Residential Building | REVIEW COMPLETED | |||
| 08/10/2026 | TW New Development Review Fast | REVIEW COMPLETED | Tucson Water has no objection to the proposed development. The site plan identifies an existing water meter proposed to serve Building 2 unit 2101. If any existing water meter(s) or service(s) are to be removed or abandoned as part of this development, please contact Tucson Water New Services to coordinate the proper abandonment. Tucson Water New Services shall also be contacted to coordinate any new water meter(s) and service connection(s) required for the proposed development. |