Permit Number: TC-MDP-0725-00398
Parcel: 120073630

Address:
3820 S LUNDY AV

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1

Permit Number - TC-MDP-0725-00398
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/29/2025 Residential Building APPROVED
07/24/2025 Fire New Construction NOT REQUIRED
08/06/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/30/2025 ROW Engineering Review REQUIRES RESUBMIT Site plan: Show existing and proposed Right-of-Way features. Provide distances and dimensions for the following:
1. Driveway (PAG SD 206) Max. width for residential driveway is 20’
2.Sidewalk (PAG SD 200) 5’ for Local roadways - Required with existing Curb present.
3. Show/Call out Electric Pole and Mailbox location.
4. expansion greater than 25%? Civil Improvements required
Note City Chapter 25 Driveway/Curb Cut standards.
Minimum Driveway width . . . . . 10 feet
Maximum Driveway width . . . . . 20 feet
Maximum Driveway width for 2 adjoining properties . . . . . 30 feet
Minimum distance between Driveway . . . . . 12 feet
Minimum distance of Driveway from street light standards, or catch basins . . . . . 5 feet
Minimum distance of Driveway from a fire hydrant of city water hydrant . . . . . 20 feet
Minimum distance of Driveway from end of a curb return . . . . . 4 feet
08/06/2025 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM:
Bobby Parsons
Zoning Section Review

PROJECT:
TC-MDP-0725-00398
3820 S. Lundy Ave. Tucson, AZ 85714
Duplex 3-2 bedroom from model master TC-MDP-0125-00002 (1st Review)

TRANSMITTAL DATE: 8/6/2025

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

1. Comment: The site plan should be designed to include the information as noted on the sample site plan. Please see https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf for reference.
2. Comment: Please draw, label, and dimension the ½ Right of Way from the centerline to the face of curb and from the face of curb to the property line along S. Lundy Avenue. Please refer to Paving Improvement Plan I-754A p. 18 if necessary. https://maps-and-records.tucsonaz.gov/construction-plans/details/I-754A.
3. Comment: Per the City of Tucson Inclusive Home Design Ordinance (https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf), all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway, sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402-404 of the ADA Accessibility Standards (https://www.access-board.gov/ada/chapter/ch04/).
4. Comment: Please draw, label, and dimension the utility easement located to the North of the parcel.
5. Comment: TC-DMO-0725-00150 is currently in needs resubmittal status. The demolition permit needs to be issued before this permit can be issued.
6. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.
07/23/2025 PDSD Application Completeness Express REVIEW COMPLETED