Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Permit Number - TC-MDP-0626-00516
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/03/2026 | Residential Building | APPROVED | |||
| 09/14/2026 | Residential Engineering | APPROVED | |||
| 09/16/2026 | Fire New Construction | NOT REQUIRED | |||
| 09/25/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/04/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston Planner PROJECT: TC-MDP-0626-00516 1701 N Camino Claveles Unit 2, Tucson, AZ 85745 ADU (1st Review) TRANSMITTAL DATE: 09/04/2026 This site is located in the RX-2 zone (UDC 4.7.7). A single-family residence is a permitted use in this zone (Table 4.8-1). RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. Attach neighbor waivers from the owners at 1820 N Westridge Av and 3085 W. Camino Camilia directly to Sheet G101. If one of more waivers cannot be obtained, a Design Development Option (DDO) is required. Per Unified Development Code (UDC) Table 6.3-2.A, the rear and side setbacks for the RX-2 zone are 20’ and not 5’ as shown on Sheet G101. The exception to the 20’ required setback would be per the Miraflores Estates No 2 subdivision development plan. The subdivision recorded (1977) prior to the property being annexed into the City of Tucson in 1992. Staff have no records of reduced setbacks for the subdivision and welcome a copy of the approved development plan if one exists. Here are sample neighbor waivers. Each waiver will need to be applied directly on the site plan. My Name is __________________ and I am the property owner of the property located at __________. I have reviewed the site plan and have no objection to the structure(s) being located or constructed _ft. from the property line as shown on the site plan. Mi hombre es ________________ y yo soy el dueño de la propiedad ubicada en la _____________________. He revisado el plan y no tengo ninguna objeción a que estructura se encuentra o construye ______ desde la línea de propiedad, como se muestra en el plan. Firma:_________ Fecha: _______. If one or more neighbor waivers cannot be obtained, here is the link to the DDO application and submittal process: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo-for-setback-and-height.pdf After filling out the application, submit under the Zoning Modification sub-record that has been created. For instructions on how to apply for a sub-record, visit the following link https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf For additional question regarding DDOs, contact Georgia Pennington at georgia.pennington@tucsonaz.gov. Please contact Georgia Pennington at georgia.pennington@tucsonaz.gov and/or Mark Castro at mark.castro@tucsonaz.gov upon completion of the application. 2. Provide Lot Coverage calculations. This includes all enclosed structures and vehicle use areas divided by the lot’s square footage per UDC 6.4.3.2.B. 3. Provide the following in the next submission packet: a. Site plan with neighbor waivers OR the Design Development Option Letter of Approval b. A response letter addressing all staff review comments. 4. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov . |
||
| 09/03/2026 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 09/25/2026 | ROW Engineering Review | REVIEW COMPLETED | |||
| 09/11/2026 | TW New Development Review Fast | REVIEW COMPLETED | Tucson Water has no objection to the proposed project. Parcel 166062210 is currently served by a 5/8-inch water meter, No. 17306207. If the existing meter will serve both the existing residence and the proposed house, the combined fixture count shall not exceed the 20-fixture limit for a 5/8-inch meter under Tucson Water’s meter sizing policy. If the combined count exceeds this limit, the owner shall contact Tucson Water New Services to coordinate a meter upgrade. If a separate water meter is needed for the proposed house, the owner shall contact Tucson Water New Services for application and installation requirements. |