Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-MDP-0625-00330
Parcel: 110061360

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1

Permit Number - TC-MDP-0625-00330
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/26/2025 Fire New Construction NOT REQUIRED
07/01/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/01/2025 Residential Building REQUIRES RESUBMIT ACTIVITY NO. TC-MDP-0625-00330
ADDRESS/PARCEL: (3945 E GLENN ST TUCSON, AZ 85712)
Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter.
COMMENTS:
1. Please show the FFE, finished floor elevation, and the RIM elevation of the nearest upstream manhole on the site plan. Will be used to determine if a backwater valve is required. (P3008.1, City of Tucson Amendments)
2. If FFE of new ADU is higher than existing residence, and existing residence doesn’t require a backwater valve, please state on the site plan.
3. Please resubmit
Contact Sean Severson with any questions: sean.severson@tucsonaz.gov
06/30/2025 Site Engineering REQUIRES RESUBMIT TC-MDP-0625-00330
3945 E GLENN ST

Site engineering comments are as follows:

1. This project lies within a recognized floodplain and requires a Floodplain Use Permit (FUP) with Elevation Certificate. Please start a new FUP at our permit application web page:
https://tdc-online.tucsonaz.gov/#/home

Isaac Tineo - isaac.tineo@tucsonaz.gov
07/01/2025 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section
PROJECT: TC-MDP-0625-00330
3945 E. Glenn St. – R-2
ADU Model Plan (1st Review)

TRANSMITTAL DATE: July 1, 2025

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) with an accessory dwelling unit (ADU) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, 8, & 9 and 6.6.3.

Provide a detailed response letter with your next submittal that clearly shows how you have addressed all Zoning comments.
1. Based on Model Plan TC-MDP-0624-00720 it appears that the porch is included in the 546 SF shown under the lot coverage. Per UDC Article 6.4.3.C.1.a Roofed areas, porches, open on at least one side are not included in the calculation.

2. Show ADU #1 as not part of this permit.

3. As you are proposing 2 ADU’s on this site separate addresses are required. Contact Pima County Addressing and secure the required addresses and revise the permit to show the correct addresses.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
06/17/2025 PDSD Application Completeness Express REVIEW COMPLETED
06/23/2025 ROW Engineering Review REVIEW COMPLETED E Glenn St is under pavement moratorium until March 31, 2027. No pavement cuts shown on plans for new utility connections.