Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Permit Number - TC-MDP-0625-00327
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/25/2025 | Site Engineering | APPROVED | |||
| 07/01/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/30/2025 | Residential Building | REQUIRES RESUBMIT | ACTIVITY NO. TC-MDP-0625-00327 ADDRESS/PARCEL: (1649 E 13TH ST Unit:UNIT 1 TUCSON, AZ 85719) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. COMMENTS: 1. The upstream manhole, #9907-68, has a rim elevation of 2432.8 and the ADUs have a FFE of 2433. FFE needs to be 12 inches higher than upstream manhole elevation. Therefore, please provide backwater valves (P3008.1, City of Tucson Amendments) 2. Please resubmit |
||
| 06/20/2025 | ROW Engineering Review | REQUIRES RESUBMIT | Site plan: Show existing and proposed Right-of-Way features. Provide distances and dimensions for the following: 1. Driveway (PAG SD 206) Max. width for residential driveway is 20’ 2. Sidewalk (PAG SD 200) 5’ for Local roadways, to include ADA complaint curb ramp. 3.Road Type: Local *Unused existing curb cuts shall be closed. Sidewalk required if existing curb exists. |
||
| 07/01/2025 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-MDP-0625-00327 1649 E 13TH ST Unit: 1. – R-2 ADU Model Plan (1st Review) TRANSMITTAL DATE: July 1, 2025 This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) with an accessory dwelling unit (ADU) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, 8, & 9 and 6.6.3. Provide a detailed response letter with your next submittal that clearly shows how you have addressed all Zoning comments. 1. Based on the “FRONT YARD SETBACK 20 FT” shown along 13th St. the proposed ADU #1 is located within the front yard. Per UDC Article 6.6.3.C and ADU is not allowed in the buildable area extending the full width of the lot between the principal building and the front street lot line. A Board of Adjustment for Variance will need to be submitted and approved for ADU #1 to be permitted as shown on the plan. 2. Per UDC Article 6.4.5.C.1.b where a lot abuts more than one street, the owner chooses which street lot line is the front lot line. From other than the front lot line, the street perimeter yard is ten feet, as measured from the street property line. The “SIDE YARD SETBACK 6FT OR 2/3H” shown along Warren is not correct and should be either 20’ or 10’. If you change the setback shown along Warren to show the 20’ setback and the 10’ setback shown along 13th ADU #1 would not be considered in the front yard as stated in comment 1. Either way you label the street perimeter yard setbacks ADU # 2 will be located within the front yard and requires a Board of Adjustment for Variance. 3. Per Construction Plan I-531 sheet 8, found at: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-531, the 30’-6” ½ R.O.W. shown for 13th is not correct and should be 30’ Also, provide a dimension from centerline to face of curb and from face of curb to the south property line. Per Construction Plan I-531 sheet 8 the distance from centerline to face of curb should be 18’ and from face of curb to south property line should be 12’. 4. Per Construction Plan I-531 sheet 13, found at: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-531, the 30.5’ ½ R.O.W. shown for Warren is not correct and should be 30’ Also, provide a dimension from centerline to face of curb and from face of curb to the south property line. Per Construction Plan I-531 sheet 13 the distance from centerline to face of curb should be 18’ and from face of curb to south property line should be 12’. 5. Show ADU #2 as not part of this permit. 6. Based on Model Plan TC-MDP-0624-00720 it appears that the porch is included in the 546 SF shown under the lot coverage. Per UDC Article 6.4.3.C.1.a Roofed areas, porches, open on at least one side are not included in the calculation. Board of Adjustment application/requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. Contact for the Board of Adjustment is Mark Castro at Mark.Castro@tucsonaz.gov. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 06/20/2025 | Fire New Construction | REVIEW COMPLETED | |||
| 06/17/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |