Permit Number: TC-MDP-0623-01163
Parcel: 11820019A

Review Status: Requires Resubmit

Review Details: MODEL PERMIT TEMPLATE REVIEW RESIDENTIAL v.1

Permit Number - TC-MDP-0623-01163
Review Name: MODEL PERMIT TEMPLATE REVIEW RESIDENTIAL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/10/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/30/2025 Residential Building REQUIRES RESUBMIT Show the address on the site plan.

Relocate the electric and water lines from the neighboring property.
11/07/2025 Residential Engineering REQUIRES RESUBMIT Permit: TC-MDP-0623-01163
Location: 1205 S HERNDON AV
Review Date: 11/07/2025
Residential Engineering Comments:
1. The provided site plan appears to be for Parcel 2 from the lot split (TD-DIV-0325-00040.) Please update to provide information for Parcel 1 AP# 118-20-019A with recorded measurements from the surveyor. Missing measurements: west boundary and south boundary.
2. Please provide and demonstrate vehicle use area for the parcel.
3. Demonstrate how the two parcels will operate independently from each other through separation either by a fence or a wall.
4. Provided lot calculations must be updated to only include “Building Area and “Vehicular Access” for Parcel 1 AP# 118-20-019A. (See mark-ups)
5. It appears the TEP POLE called out on the North is in the wrong position, please update position to the
If you have any questions or concerns, please contact
Dylan Molina
Dylan.Molina@tucsonaz.gov
11/10/2025 Residential Zoning REQUIRES RESUBMIT CDRC Transmittal

FROM: Loran Shamis, Principal Planner
PDSD Zoning Review Section

PROJECT: TC-MDP-0623-01163
Residential - Single Family Residential
1205 S Herndon Avenue

TRANSMITTAL DATE: November 10, 2025

DUE DATE: October 29, 2025

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

The proposed use is Residential – Single Family Residential and the site is zoned R-3 which permits Residential – Single Family Residential subject to use specific standard 4.9.7.B.6 (UDC 4.8.4).

01. COMMENT: Some of the information of the site plan is outdated since the site has been split through permit number TD-DIV-0325-00040. Please update the setbacks to the south and east to the new parcel lines since the lot split has been approved. They do not appear to be correct in the project data because they do not match the dimensions provided on the site plan.

02. COMMENT: The lot coverage calculations need to be updated. R-3 allows a maximum lot coverage of 70% The lot coverage calculation on the site plan accounts for the entire parcel prior to the lot being splits. Update the lot coverage calculation to be a percentage of the square footage for Parcel 1 as presented on application TD-DIV-0325-00040 The site plan states the total lot is 12,574 square feet and Parcel 1 on application TD-DIV-0325-00040 states the lot size is 5,603.3 square feet and 0.13 acres.

03. COMMENT: This permit is for 1205 S. Herndon Avenue, not 1225 S. Herndon Avenue. Revise the plans to highlight the proposed improvements on 1205 S. Herndon Avenue as appropriate.


For questions regarding Zoning comments, please contact me at: Loran.Shamis@tucsonaz.gov
10/29/2025 PDSD Application Completeness Express REVIEW COMPLETED