Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Permit Number - TC-MDP-0623-01163
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/06/2024 | Site Engineering | APPROVED | |||
| 03/22/2024 | Fire New Construction | NOT REQUIRED | |||
| 03/22/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/26/2024 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-MDP-0623-01163 (391 W 22ND ST TUCSON, AZ 85713) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC). Plumbing Review: 1. Provide elevation measurements for Next Upstream Manhole and Finished Floor Elevation. Provide Backwater valve protection as/if required. Backwater valve protection: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/building-code/2018_-_irc_amendments.pdf Section P3008.1 Electrical Review: 2. Notate on the Site Plan the overhead electrical clearance requirements: a. Provide 10’ clearance above pedestrian accessible areas, 2017 NEC 230.24(B)(1) b. Provide 12’ clearance above residential property and driveways (Voltage under 300v), 2017 NEC 230.24(B)(2) Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 01/29/2024 | ROW Engineering Review | REQUIRES RESUBMIT | TC-MDP-0623-01163 (391 W 22ND ST TUCSON, AZ 85713) Please resubmit revised drawings along with a detailed response letter which states how all comments were addressed. Comments: 1. MS&R - Please move the parking out of the future ROW area. 2. There is no need to show vehicle maneuvering for a SFR. Residents can back into the street on a local road. However, DTM will not permit vehicle access to a SFR off of an arterial if an alternative is available (AMG). So, please remove the depiction from the plan showing vehicle maneuvering creating access to 22nd St frontage. 3. S Herndon Pl is labeled as an unpaved road, but it is paved. Faffs Riederer Faffs.Riederer@tucsonaz.gov Abbreviations: City of Tucson Code (COTC), Unified Development Code (UDC) Administrative Manual (AM), Technical Standards Manual (TSM), Street Design Guide (SDG), Pima Association of Governments Standard Details (P. A. G. SD), Access Management Guidelines (AMG), Major Streets and Routes Plan (MS&R), City of Tucson Public Utility Administrative Manual (PUAM), City of Tucson Department of Transportation and Mobility (COT DTM). |
||
| 01/25/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: TC-MDP-0623-01163 Duplex 391 W 22ND ST Zoning R-3 TRANSMITTAL DATE:January 25, 2024 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: As 10th AV is a Major Street and route show the existing and future Right-of-Way, Additional comment may be forthcoming. If you have any questions about this transmittal, Contact Zone1.desk@tucsonaz.gov |
||
| 01/25/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |