Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Permit Number - TC-MDP-0526-00339
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/20/2026 | Residential Building | APPROVED | |||
| 05/29/2026 | Fire New Construction | NOT REQUIRED | |||
| 06/01/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/15/2026 | Addressing Validation | REQUIRES RESUBMIT | Please update the site plan to include the Unit Number of the proposed residence (there are multiple unit numbers associated with this address). | ||
| 06/01/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit: TC-MDP-0526-00339 Location: 5850 S FONTANA AV Review Date: 6/1/2026 A Comment Response letter is required. Please address all reviewer’s comments in a separate document with all required documents for resubmittal. Residential Engineering Comments: 1. Revise the site plan and cover sheet. The subject lot (Lot 4) was recently part of a minor lot subdivision under TC-DIV-0625-00068, Sequence No(s) 20260370637/ 20260680480 and recorded on 2/04/2026 and 3/9/2026 respectively. Please update the lot information and revise the plans to match this minor lot subdivision. 2. The new dwelling requires an exterior accessible route that shall conform to 2017 ICC A117.1 Sections 402 and 403 and City of Tucson Inclusive Home Design Ordinance. Water draining from roof shall not interfere with exterior accessible route. Please update site plan to include a general note regarding City of Tucson requirements for Inclusive Design. Show the accessible route on the site plan. If you have any questions or concerns, please contact Dylan Molina. Dylan.Molina@tucsonaz.gov |
||
| 05/20/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston Planner PROJECT: TC-MDP-0526-00339 5850 S Fontana AV., Tucson, AZ 85706 SFR (1st Review) TRANSMITTAL DATE: 05/20/2026 This site is located within the R-2 Zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. Resubmit the site plan and cover sheet. The subject lot (Lot 4) was recently resubdivided under TC-DIV-0625-00068, Sequence No. 20260370637 and recorded on 2/04/2026. Please update the lot information and revise the plans to match this resubdivision. 2. Provide all information required for a ‘Full’ site plan. For instructions on what is to be included, visit the following link: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Site-Plan-Examples 3. Demonstrate how landscaping requirements have been met on Sheet A1.1. This sheet provides details, yet these are not reflected within the boundaries of the lot. Here are the landscape requirements: https://middle-housing-cotgis.hub.arcgis.com/pages/Residential-Landscaping-Code 4. Per the City of Tucson Inclusive Home Design Ordinance (https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf), all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway (or apron), sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402-404 of the ADA Accessibility Standards (https://www.access-board.gov/ada/chapter/ch04/). See TSM 7-01.4.3 for specifications, including slope and composition materials. 5. This project includes an SFR model template (Model Master Plan TC-MDP-0326-00103) Show all utilities including any that may be in use by the shed located on the west side of the lot, if this shed is located on the subject lot. 6. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. The City of Tucson Unified Development Code (including the most recent amendments) may be accessed here: www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov . |
||
| 05/29/2026 | ROW Engineering Review | REQUIRES RESUBMIT | Site Plan Show proposed utility connections. |
||
| 05/22/2026 | TW New Development Review Fast | REQUIRES RESUBMIT | Based on Tucson Water records, this parcel is currently served by an existing 5/8-inch water meter, Meter No. 240786983. The proposed residence appears to be served from the same water service/meter as the existing dwelling units on the parcel. Please provide the fixture unit count for each existing residence and for the proposed residence. Based on Tucson Water meter sizing, a 5/8-inch water meter can accommodate a maximum of 20 fixture units. Tucson Water will review the total fixture unit count to determine whether the existing meter has adequate capacity or if a meter upgrade will be required. |
||
| 05/15/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |