Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2
Permit Number - TC-MDP-0526-00339
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/29/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/29/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit: TC-MDP-0526-00339 Location: 5840 S FONTANA AV UNIT 3 Review Date: 6/29/2026 A Comment Response letter is required. Please address all reviewer’s comments in a separate document with all required documents for resubmittal. Residential Engineering Comments: 1. The new site plan has no space for turn-around area for a vehicle, nor does the exterior accessible route connect to a PAG driveway. Proposed accessible route does not currently conform to 2017 ICC A117.1 Sections 402 and 403 and City of Tucson Inclusive Home Design Ordinance. 2. Next submission must show an overall site plan with all existing and proposed structures with the dimensioned distances from property lines and structures. This supplemental site plan must show all parcels on recently approved lot split: TD-DIV-0625-00068, 20260370637/20260680480. 3. Shared parking is only permissible between 4 dwellings, else, the site will be viewed as a commercial site. 4. Address these comments and related comments from Zoning and ROW in a comment response letter. If you have any questions or concerns, please contact Dylan Molina. Dylan.Molina@tucsonaz.gov |
||
| 06/16/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Erick Bieber Planning & Development Services Department – Zoning Review Section PROJECT: TC-MDP-0526-00339 5840 S Fontana Ave Unit 3, Tucson, AZ 85706 Residential Model Permit TRANSMITTAL DATE: June 16th, 2026 This site is located in the R-2 zone (UDC 4.7.9). Middle Housing is a permitted use in this zone subject to use-specific standards 4.9.7.B.6, .8, .9 and 11-14. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. (Comment) This comment was not fully addressed: “Resubmit the site plan and cover sheet. The subject lot (Lot 4) was recently resubdivided under TC-DIV-0625-00068, Sequence No. 20260370637 and recorded on 2/04/2026. Please update the lot information and revise the plans to match this resubdivision.” The lot information on the cover sheet has not been updated to reflect the minor subdivision. Please update the address, parcel, and legal description under Project Data. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov |
||
| 06/17/2026 | ROW Engineering Review | REQUIRES RESUBMIT | Site Plan Show existing curb cut opening width and proposed driveway width. max 30' for shared driveway. min. 10' for residential. 5' min. for utility poles, guy wire is also in the way. |
||
| 06/12/2026 | Addressing Validation | REVIEW COMPLETED | |||
| 06/12/2026 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 06/24/2026 | TW New Development Review Fast | REVIEW COMPLETED | Comments addresed , Tucson Water has no objection. |