Permit Number: TC-MDP-0525-00313
Parcel: 136192010

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1

Permit Number - TC-MDP-0525-00313
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/06/2025 Fire New Construction NOT REQUIRED
06/23/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/02/2025 ROW Engineering Review REQUIRES RESUBMIT Site plan: Show existing and proposed Right-of-Way features. Provide distances and dimensions for the following:
1. Driveway (PAG SD 206) Max. width for residential driveway is 20’
2.Sidewalk (PAG SD 200) 6’ for arterial roadways.
3.Road Type: Arterial Right of Way
4.For collector/arterial roadways, show onsite vehicle maneuverability.
*Unused existing curb cuts shall be closed.
06/23/2025 Site Engineering REQUIRES RESUBMIT TC-MDP-0525-00313
8055 E ESCALANTE RD

Site Engineering comments are as follows:

1. Site Engineering cannot approve this model building permit until the site plan has been updated to reflect the changes required by the Building and ROW Engineering comments.
2. Please show vehicle maneuverability and current and future right-of-way.
3. The plan shall be drawn using an engineering scale.
4. As there is a land division in review for the neighboring lot to the west, please provide a letter describing the future plan for the resulting parcels. If they are to be developed in a similar manner to this permit submittal, please include an overall site plan which includes improvements in alignment with the requirements of sites that function as a multi-family development.
Ryan Insalaco – ryan.insalaco@tucsonaz.gov
06/17/2025 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-MDP-0525-00313
8055 E ESCALANTE RD. – C-1
SFR w/ Attached ADU (1st Review)

TRANSMITTAL DATE: June 17, 2025

Provide a detailed response letter with your next submittal that clearly shows how you have addressed all Zoning comments.

This site is located in the C-1 zone (UDC 4.7.20). A single-family residence (SFR) with an attached accessory dwelling unit (ADU) is a permitted use in the zone (UDC Table 4.8-4), subject to Use Specific Standards 6.6.3

1. The lot coverage does not appear to be correct and does not include the entire vehicle access to the parking shown on the plan. Also the lot coverage shall be based on the future ROW, see comment 4 below.

2. The plot plan shall be drawn at an engineering scale, i.e. 1” = 10, 1” =20’.

3. Provide the legal description, “LAKESIDE NO 2 E50' W1050' S235' BLK 2” on the plot plan.

4. Escalante Rd. is designated as an Arterial on the COT MS&R Map, found at, https://www.tucsonaz.gov/Departments/Planning-Development-Services/Development-Tools-Resources/Plans#section-5and has a future right-of-way of 150’. As the existing (ROW) is not at the full 150’ ROW show the future ROW line along with the future curb and sidewalk fully dimensioned based on the road cross section found on page 15 of the COT MS&R Plan found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Development-Tools-Resources/Plans#section-5.

5. As Escalante Rd. is designated as an Arterial on the COT MS&R Map clearly demonstrate that a parking vehicle can turn around on site with out needed to back out into the ROW.

6. Per UDC Table 6.3-4.A the minimum perimeter yard setback from the SFR/ADU to the west property line is 10’-0” or ¾ (H), greater of the two. Based on a wall height of less than 13’-4” the required perimeter yard setback is 10’-0”, proposed setback is 6’-0”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
05/30/2025 PDSD Application Completeness Express REVIEW COMPLETED
06/12/2025 Residential Building REVIEW COMPLETED