Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Permit Number - TC-MDP-0524-00626
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/13/2024 | ROW Engineering Review | APPROVED | No Comments | ||
09/11/2024 | Fire New Construction | NOT REQUIRED | |||
09/23/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
09/10/2024 | Residential Building | REQUIRES RESUBMIT | TC-MDP-0824-00897 – Units 1/2 T22-M0037 TC-MDP-0824-00898 – Units 3/4 T22-M0037 TC-MDP-0824-00899 – Units 5/6 T22-M0037 TC-MDP-0824-00896 – Units 7/8 T22-M0037 TC-MDP-0524-00626 – Units 9/10 T22-M0037 TC-MDP-0424-00380 – Units 11/12 T22-M0037 Fire separation: The line used to determine fire separation distance is an imaginary line drawn between the two structures. 1. Any structure placed within the 3-foot fire separation distance, from the line used to determine the fire separation distance, requires not less than one-hour fire-resistive construction for reducing fire spread across the line, R302.1(City of Tucson Amended). Fire rated materials are found in IBC Table 721.1(2), Items 15-1.1 to 16-1.3. No windows, doors or vents are allowed in the fire rated wall assembly. 2. Roof projections extending into the 3-foot fire separation distance require not less than one-hour fire-resistive construction on the underside, R302.1 (City of Tucson Amended). The fire protected overhang may not extend closer than 24” from the line used to determine the fire separation distance. 3. The minimum distance between structures, with no fire rated wall assembly, is 6’ and a maximum 1’ overhang. Outdoor lighting: 1. Show the location of all proposed outdoor lighting fixtures which ones are full cut-off (FCO) style 2. Provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. Provide the manufacturer’s spec sheets for the lighting fixtures. 3. Show lamps with a maximum of 3500K color temperature, OLC 402.1. 4. Full Cut Off fixtures under an overhang or canopy are exempt from the calculation, OLC 4.2.1. TD-DEV-0124-00022 Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
09/23/2024 | Site Engineering | REQUIRES RESUBMIT | see zoning comment | ||
09/18/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-MDP-0524-00626 4151 E 22ND ST. – O-3 Multifamily (1st Review) TRANSMITTAL: September 18, 2024 This site is located in the O-3 zone (4.7.15 ). Multifamily use is a permitted use in the zones (UDC Table 4.8-3). 1. The provided development package sheet is not the correct sheet. Provide sheet 2 of the approved TD-DEV-0124-00022 with your next submittal. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
09/06/2024 | PDSD Application Completeness | REVIEW COMPLETED |