Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-MDP-0523-01025
Parcel: 11808081B

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL PERMIT - SUBDIVISION v.2

Permit Number - TC-MDP-0523-01025
Review Name: SITE FROM MODEL PERMIT - SUBDIVISION v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/01/2023 Residential Building APPROVED
11/07/2023 Site Engineering APPROVED
11/07/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/07/2023 ROW Engineering Review REQUIRES RESUBMIT TC-MDP-0523-01025 (972 W SILVERLAKE RD TUCSON, AZ 85713)

Please resubmit revised drawings along with a detailed response letter which states how all comments were addressed.

Comments:
1. Please show the width of existing sidewalks.
2. TSM 10-01.5.1, AM 2-06.4.9 – Please provide future and existing sight visibility triangles. Reference TSM 10-01.5.1 for instructions.
The SVTs on the plan are oriented the wrong way. The long side of the triangle goes against the edge of the travel lane (the far side of the bike lane). Please show that the SVT (current) is clear of the wall. You may have to shift the western edge of the driveway east in order to get the SVT clear of the wall (or remove part of the wall).
Faffs Riederer
Faffs.Riederer@tucsonaz.gov

Abbreviations: City of Tucson Code (COTC), Unified Development Code (UDC) Administrative Manual (AM), Technical Standards Manual (TSM), Street Design Guide (SDG), Pima Association of Governments Standard Details (P. A. G. SD), Access Management Guidelines (AMG), Major Streets and Routes Plan (MS&R).
11/07/2023 Site Zoning REQUIRES RESUBMIT FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: TC-MDP-0523-01025
972 W SILVERLAKE RD Zoning R-1 .
New Duplex

TRANSMITTAL DATE:‎November 7, 2023


COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

1..COMMENT:Provide a calculation demonstrating how UDC section 4.9.7.B.3 is met. Per UDC section 4.9.7.B.3. One dwelling must be at least 25% smaller than the other dwelling.

2.COMMENT: Revise the setback on Santa Cruz Ln, Per UDC section 6.4.5.C.1.b “Where a lot abuts more than one street, the owner chooses which street lot line is the front lot line . From other than the front lot line , the street perimeter yard is ten feet, as measured from the street property line”


If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov
11/01/2023 PDSD Application Completeness Express REVIEW COMPLETED
11/07/2023 Site Landscape REVIEW COMPLETED