| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/14/2023 | Residential Building | APPROVED | |||
| 01/09/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/09/2024 | ROW Engineering Review | REQUIRES RESUBMIT | TC-MDP-0523-00949 (825 E 36TH ST Unit:UNIT 1 TUCSON, AZ 85713) Internal Note: This permit was copied from permit Number# TC-MDP-1222-00078 Please resubmit revised drawings along with a detailed response letter which states how all comments were addressed. Comments: 1. This property is partially within the Downtown Airport Wash COT FHA Local Flood Hazard Area. This development will need a Floodplain Use Permit if the proposed structures are within the flood boundary. Please show the boundary on the site plan. 2. The north-south dimensions on the plans are wrong as the lots taper due to layout discrepancies over a 100-yrs ago. The west north-south dimension should be 140.655' and not the 139.65' as noted. 139.65' is the dimension at the west end of the block. The east edge of the plan would have an even greater dimension north-south as you increase in distance as you head east. (Reference: https://www.asr.pima.gov/ParcelData/Map/Arm/MP02/02039_02.PDF) Faffs Riederer Faffs.Riederer@tucsonaz.gov |
||
| 01/05/2024 | Site Engineering | REQUIRES RESUBMIT | 1. Provide a dimension from the edge of travel way to the first parking spot onsite to verify that the throat length is a min. 60 feet. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
||
| 12/20/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: TC-MDP-0523-00949 823 E 36TH ST Zoning C-2 TRANSMITTAL DATE: December 20, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: 1.Provide a dimension from the centerline of 36th st to the face of curb and from the face of curb to the south street property line, Provide the future property line. 2. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a wall height of 9’-6” the required perimeter yard setback from the proposed SFR to the east and west property line is 6’-4”, proposed setback is 6’-0”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback, DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. If you have questions about the DDO application or process please contact Wyatt Berger at wyatt.berger@tucsonaz.gov or Georgia Pennington at georgia.pennington@tucsonaz.gov If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
| 12/11/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 01/08/2024 | Site Landscape | REVIEW COMPLETED |