Permit Review Detail
Review Status: In Review
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Permit Number - TC-MDP-0426-00263
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| N/A | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| N/A | Fire New Construction | PENDING ASSIGNMENT | |||
| N/A | Residential Building | PENDING ASSIGNMENT | |||
| N/A | Residential Zoning | PENDING ASSIGNMENT | |||
| N/A | ROW Engineering Review | PENDING ASSIGNMENT | |||
| N/A | TW New Development Review Fast | PENDING ASSIGNMENT | |||
| 04/29/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit Activity Number: TC-MDP-0426-00263 (1st Review) Project: New 2 story duplex model plan Location: 1744 W VALDEZ CT Review Date: 4/29/2026 Reviewer: Marco Contreras – Engineering Associate - Site Engineering Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter review time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. Provide a response letter addressing each comment with location of change on the plans. Submit the separate response letter and plan set files. Site Engineering Review Comments: 1. Denote the FFE and FG as established by the associated tentative plat. 2. Provide an acceptable scale to the plan set. 3. As the proposed development is a new dwelling (ADU, SFR, Duplex, Etc), Per the City of Tucson Inclusive Home Design Ordinance: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf, all new dwellings and units have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway, sidewalk, or street to an accessible entrance. a. Refer to Technical Standards Manual Section 7-01.4.3 for sidewalk/pathway specifications including the minimum 4ft-width and composition minimums. b. Action Items: Provide a width call-out, proposed slope, and label the walkway as the “Accessible Route” leading to the new home entrance If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov |
||
| 04/28/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |