Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Permit Number - TC-MDP-0324-00364
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/16/2024 | ROW Engineering Review | APPROVED | No Comments David Stiffey David.Stiffey@tucsonaz.gov |
||
| 04/05/2024 | Fire New Construction | NOT REQUIRED | |||
| 04/16/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/11/2024 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-MDP-0324-00364 (3626 E BELLEVUE ST TUCSON, AZ 85716) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1. Show the sewer connection from the dwellings to an approved Pima County sewer system. 2. The direction of the line will pass into or through a separate parcel. This sewer line must pass through a recorded easement on the adjoining parcel and be shown on these plans. 3. Provide the Recorded Easement documentation. 4. Each dwelling (or group of dwellings on the same parcel 12218225A) requires an independent sewer connection from the dwelling to the Pima County sewer connection. 2018 IPC 701.3. These two units can share the connection, but they cannot share a connection with the units on the adjoining parcels. A joint sewer agreement requires an appeal to the building official for approval. 5. Provide the finished floor and rim elevation of the upstream manhole cover in the sewer, https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/building-code/2018_-_irc_amendments.pdf Section P3008.1. 6. Provide Backwater valve protection as/if required. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 04/16/2024 | Site Engineering | REQUIRES RESUBMIT | 1. Provide a recorded easement document that proves that this parcel has access from the street. Lianne Evans lianne.evans@tucsonaz.gov |
||
| 04/16/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-MDP-0324-00364 3626 E BELLEVUE ST. – R-2 Duplex (1st Review) TRANSMITTAL DATE: April 16, 2024 This site is located in the R-2 zone (UDC 4.7.9). A Duplex is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). 1. The north/south property distance does not appear to be correct. 2. Provide a lot coverage calculation that meets the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example, 3. Clarify why there are 9 drawings listed under the drawing index but only on sheet was submitted. 4. Clearly demonstrate how legal access is provided to this site. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 04/01/2024 | PDSD Application Completeness Express | REVIEW COMPLETED | The plan submitted shows to be for a duplex. The location does not have units attached to the address and a pre issuance addressing condition has been placed on permit. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to verify and add the units. Note, a resubmittal and a request for address change may be required. |