Permit Number: TC-MDP-0324-00271
Parcel: 138102030

Address:
120 E DREXEL RD

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1

Permit Number - TC-MDP-0324-00271
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/26/2024 Fire New Construction NOT REQUIRED
03/26/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
03/26/2024 Residential Building REQUIRES RESUBMIT Permit Review TC-MDP-0324-00271 (120 E DREXEL RD TUCSON, AZ 85706)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC).

SITE PLAN:
1. Indicate the location and size of buildings, utility meters and lines supporting the alterations, R106.1.1. Show all utility lines from their source to the dwelling.

2. Provide elevation measurements for Next Upstream Manhole and Finished Floor Elevation. Provide Backwater valve protection as/if required.
Backwater valve protection:
https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/building-code/2018_-_irc_amendments.pdf Section P3008.1 Where required. Where the finish floor elevation is less than 12 inches above the elevation of the next upstream manhole cover in the sewer, a backwater valve shall be installed in the building drain or branch of the building drain serving that floor.


Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
03/26/2024 ROW Engineering Review REQUIRES RESUBMIT TC-MPD-0324-00271
120 E. Drexel Rd.

Comments:
1. Please note on your plan that the entryway will be constructed with P.A.G. standard 213 concrete header returns with 18’ radius.
2. Note on the plan that the asphalt in the entrance will be paved with City Mix No. 2

David Stiffey
DTM Project Coordinator
David.Stiffey@tucsonaz.gov
03/25/2024 Site Engineering REQUIRES RESUBMIT Schedule Inspection - "ENGR - Engineering Pre-Construction" for TD-DEV-0123-00121 prior to submission of Model Permits. Site conditions and grading must be verified prior to approval of building permit.
Joshua Garcia
joshua.garcia@tucsonaz.gov
03/26/2024 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-MDP-0324-00271
120 E DREXEL RD. – R-2
New Duplex (1st Review)

TRANSMITTAL DATE: March 26, 2024

This site is located in the R-2 zone (UDC 4.7.9). A duplex is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10.

1. The lot coverage calculation is not correct. Per UDC Article 6.4.3.B.3.b Vehicular use areas, measured within the outside edges of any area allocated to vehicle use, whether improved or unimproved, are included in the lot coverage.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
03/25/2024 PDSD Application Completeness REVIEW COMPLETED