Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Permit Number - TC-MDP-0324-00271
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/26/2024 | Fire New Construction | NOT REQUIRED | |||
03/26/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
03/26/2024 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-MDP-0324-00271 (120 E DREXEL RD TUCSON, AZ 85706) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). SITE PLAN: 1. Indicate the location and size of buildings, utility meters and lines supporting the alterations, R106.1.1. Show all utility lines from their source to the dwelling. 2. Provide elevation measurements for Next Upstream Manhole and Finished Floor Elevation. Provide Backwater valve protection as/if required. Backwater valve protection: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/building-code/2018_-_irc_amendments.pdf Section P3008.1 Where required. Where the finish floor elevation is less than 12 inches above the elevation of the next upstream manhole cover in the sewer, a backwater valve shall be installed in the building drain or branch of the building drain serving that floor. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
03/26/2024 | ROW Engineering Review | REQUIRES RESUBMIT | TC-MPD-0324-00271 120 E. Drexel Rd. Comments: 1. Please note on your plan that the entryway will be constructed with P.A.G. standard 213 concrete header returns with 18’ radius. 2. Note on the plan that the asphalt in the entrance will be paved with City Mix No. 2 David Stiffey DTM Project Coordinator David.Stiffey@tucsonaz.gov |
||
03/25/2024 | Site Engineering | REQUIRES RESUBMIT | Schedule Inspection - "ENGR - Engineering Pre-Construction" for TD-DEV-0123-00121 prior to submission of Model Permits. Site conditions and grading must be verified prior to approval of building permit. Joshua Garcia joshua.garcia@tucsonaz.gov |
||
03/26/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-MDP-0324-00271 120 E DREXEL RD. – R-2 New Duplex (1st Review) TRANSMITTAL DATE: March 26, 2024 This site is located in the R-2 zone (UDC 4.7.9). A duplex is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. 1. The lot coverage calculation is not correct. Per UDC Article 6.4.3.B.3.b Vehicular use areas, measured within the outside edges of any area allocated to vehicle use, whether improved or unimproved, are included in the lot coverage. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
03/25/2024 | PDSD Application Completeness | REVIEW COMPLETED |