Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Permit Number - TC-MDP-0224-00195
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/21/2024 | Site Engineering | APPROVED | |||
| 02/21/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/20/2024 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-MDP-0224-00195 (810 N GRANDE AV TUCSON, AZ 85745) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1. Provide elevation measurements for Next Upstream Manhole and Finished Floor Elevation. Provide Backwater valve protection as/if required. Backwater valve protection: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/building-code/2018_-_irc_amendments.pdf Section P3008.1 Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 02/08/2024 | ROW Engineering Review | REQUIRES RESUBMIT | Site Plan Show existing Right-of-Way features; see plot plan example. Provide distances and dimensions for the following: 1. Driveway 2. Curb and curb cuts 3. Sidewalk Show future Right-of-Way limits per MS&R. Grande Ave is an arterial roadway, show onsite maneuverability. See DTM comment file in attachments for reference. |
||
| 02/09/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-MDP-0224-00195 810 N GRANDE AV. – C-1 New Duplex (1st Review) TRANSMITTAL DATE: February 9, 2024 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the C-1 zone (UDC 4.7.20). A duplex is a permitted use in this zone (Table 4.8-4). 1. It appears that some type of land split is proposed. This process must be approved prior to approval of this plan. 2. Provide a dimension from centerline of Grande Ave to the face of curb and from face of curb to the west property line. 3. As Grande Ave is designated as a Arterial on the COT MS&R map clearly demonstrate that a vehicle can clearly turn around on state and drive out onto Garnde without backing into the right-of-way. Fully dimension the maneuvering area on the plan, all maneuvering must be on site. 4. Per UDC Article 6.4.3.B.3.b the lot coverage calculation shall include all vehicle use areas, whether improved or unimproved. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 02/14/2024 | Fire New Construction | REVIEW COMPLETED | |||
| 02/08/2024 | PDSD Application Completeness Express | REVIEW COMPLETED | Contact Pima County Addressing to add unit 1 and unit 2 to the address |