| 03/08/2023 | Site Engineering | APPROVED | |||
| 03/08/2023 | Site Landscape | APPROVED | |||
| 03/09/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/09/2023 | Residential Building | REQUIRES RESUBMIT | Review notes: 1. Provide elevation measurements for Next Upstream Manhole and Finished Floor Elevation. Provide Backwater valve protection as/if required. Backwater valve protection: https://www.tucsonaz.gov/files/integrated-planning/pdsd/2018_-_IRC_Amendments.PDF Section P3008.1 Where required. REVISE Section by DELETING entire paragraph and ADDING new text as follows: Where the finish floor elevation is less than 12 inches above the elevation of the next upstream manhole cover in the sewer, a backwater valve shall be installed in the building drain or branch of the building drain serving that floor. Floors discharging from above that reference point shall not discharge through the same back water valve. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 03/07/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-RES-0223-005341 4363 E Grant Rd. – R-2 SFR (1st Review) TRANSMITTAL DATE: March 7, 2023 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. As Grant Rd. is designated on the COT MS&R map as an Arterial front street perimeter yard setbacks are per UDC Article 6.4.5.C.2 & Table 6.4.5.C-1, ADT of 1,000 or greater. The setback is the greater of 21’ or the height of the proposed exterior building wall, as measured from the back of future curb. Show the future curb and if applicable the future right-of-way line on the plan and provide location dimensions and then provide a dimension from the back of future curb to the proposed dwelling unit. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov |
||
| 03/06/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |