Permit Number: TC-MDP-0223-00537
Parcel: 11008143A

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-MDP-0223-00537
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/08/2023 Site Engineering APPROVED
03/09/2023 NPPO NOT REQUIRED
03/09/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/09/2023 Residential Building REQUIRES RESUBMIT Provide elevation measurements for Next Upstream Manhole and Finished Floor Elevation. Show Backwater valve protection as/if required.

Backwater valve protection:
https://www.tucsonaz.gov/files/integrated-planning/pdsd/2018_-_IRC_Amendments.PDF
Section P3008.1 Where required. REVISE Section by DELETING entire paragraph and ADDING new text as follows: Where the finish floor elevation is less than 12 inches above the elevation of the next upstream manhole cover in the sewer, a backwater valve shall be installed in the building drain or branch of the building drain serving that floor. Floors discharging from above that reference point shall not discharge through the same back water valve.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
03/07/2023 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review

PROJECT: TC-RES-0223-00537
4369 E Grant Rd. – R-2
SFR (1st Review)

TRANSMITTAL DATE: March 7, 2023

Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

1. As Grant Rd. is designated on the COT MS&R map as an Arterial front street perimeter yard setbacks are per UDC Article 6.4.5.C.2 & Table 6.4.5.C-1, ADT of 1,000 or greater. The setback is the greater of 21’ or the height of the proposed exterior building wall, as measured from the back of future curb. Show the future curb and if applicable the future right-of-way line on the plan and provide location dimensions and then provide a dimension from the back of future curb to the proposed dwelling unit.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov
03/06/2023 PDSD Application Completeness Express REVIEW COMPLETED