Permit Number: TC-MDP-0223-00531
Parcel: 140241080

Address:
1343 E GINTER RD

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-MDP-0223-00531
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/04/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/04/2023 Residential Building REQUIRES RESUBMIT Permit Review TC-MDP-0223-00531 (1343 E GINTER RD TUCSON, AZ 85706)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken.
Code reference, 2018 International Residential Code (IRC).

1. Aerial views of the property shows that the electrical is located to the north of the structure. I don’t see any power source located to the south. Provide corrected plans showing power source in the correct location, or provide documentation showing TEP power source on the south side of the property.
2. Provide a Special Inspections Certificate for Post Tension slab, or any other special inspections required.
3. Provide elevation measurements for Next Upstream Manhole and Finished Floor Elevation. Provide Backwater valve protection as/if required.
Backwater valve protection:
https://www.tucsonaz.gov/files/integrated-planning/pdsd/2018_-_IRC_Amendments.PDF
Section P3008.1 Where required. Where the finish floor elevation is less than 12 inches above the elevation of the next upstream manhole cover in the sewer, a backwater valve shall be installed in the building drain or branch of the building drain serving that floor. Floors discharging from above that reference point shall not discharge through the same back water valve.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
05/02/2023 Site Engineering REQUIRES RESUBMIT 1. Include flow arrows or spot elevations indicating the proposed stormwater drainage on site.
2. There is an existing building on the site. Apply for a separate demolition permit for the demolition of the existing building.

Lianne Evans
lianne.evans@tucsonaz.gov
05/01/2023 Site Landscape REQUIRES RESUBMIT See zoning comments.
05/01/2023 Site Zoning REQUIRES RESUBMIT FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: TC-MDP-0223-00531
1343 E GINTER RD Zoning MH-1

TRANSMITTAL DATE:‎May 1, 2023


COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

1.COMMENT: Provide the owners information, provided in the link below is the residential plot plan requirements.
https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf

2.COMMENT: It appears that there is another structure onsite, clarify if the application is proposing to demo these structures if so a demolition permit will be required, additional comments may be forthcoming.



If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov
05/01/2023 PDSD Application Completeness Express REVIEW COMPLETED A wastewater receipt have not been submitted and will be required