Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-MDP-0123-00316
Parcel: 13601008S

Address:
2405 S CLOVIS PL

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1

Permit Number - TC-MDP-0123-00316
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/12/2024 Residential Building APPROVED
01/16/2024 Site Engineering APPROVED
01/11/2024 Fire New Construction NOT REQUIRED
01/11/2024 ROW Engineering Review NOT REQUIRED Streets are private.
01/16/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
01/05/2024 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-MDP-0123-00316
2405 S. Clovis Pl. – C-2
New SFR (1st Review)

TRANSMITTAL DATE: January 5, 2024

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-3 zone (UDC 4.7.21). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-4).

1. Per UDC Table 6.3-4.A: DIMENSIONAL STANDARDS FOR THE C-1, C-2, C-3, OCR-1, & OCR-2 ZONES, C-2 Zone Res Use to Nonres Zone the required perimeter yard setback from the proposed SFR to the south property line is 10' or ¾(H), = Height of the proposed exterior building wall, greater of the two dimensions. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Based on the elevations provided on TC-MDP-1222-00023 and a wall height of 15’-0” the required perimeter yard setback to the south property line is 11’-4”, proposed setback is 10’-0”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
01/04/2024 PDSD Application Completeness REVIEW COMPLETED