Permit Review Detail
Review Status: Requires Resubmit
Review Details: SHIPPING CONTAINER v.1
Permit Number - TC-FBB-1125-00143
Review Name: SHIPPING CONTAINER v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/05/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/26/2025 | Commercial Building - Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-FBB-1125-00143 ADDRESS: 2469 N COUNTRY CLUB RD Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. COMMENTS: 1. TRANSFORMER a. Please locate the transformer on your drawing. b. Please enter the distance in feet from the transformer to the container. 2. UTILITIES a. Please confirm whether there are any utilities connected to this container such as electric. If electricity is used for example, please provide the information onto the drawing. 3. ANCHORING SYSTEM a. Please provide anchoring system. Per code, structure to be anchored to earth. b. Provide information as to how many are to be used and locate them on your drawing. 4. Please resubmit. Should you have any questions about these comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976. |
||
| 12/02/2025 | Site Engineering - Standard | REQUIRES RESUBMIT | Permit: TC-FBB-1125-00143 Location: 2469 N COUNTRY CLUB RD Review Date: 12/2/2025 Site Engineering Comments: 1. This project lies within a City of Tucson Treat Avenue Undefined Shallow Flow floodplain and will require the submission of a floodplain use permit with elevation certificate. The FPU permit is a separate permit that can be submitted within the sub-records tab of this building permit on TDC online. 2. Due to the floodplain, it will be required that each Conex container be flood vented and affixed to the ground. Due to the flood venting requirement, the floodplain use permit process will include elevation certificate to verify the construction and placement of the flood vents. 3. For the container, flood venting will be required according to Tucson Code PART II Chapter 26, Section 26-11.2.(8). For resubmission of the building permit and submission for the flood plain use permit, have the flood vents delineated on the construction plans along with a detail showing the dimensions of the vents as well as height of vents above grade. 4. A minimum of two openings will be required for each container. The vents will have a total net area of not less than one square inch for every square foot of enclosed area. Openings may be equipped with screens, louvers, valves, or other coverings or devices if they permit the automatic entry and exit of floodwater. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 01/05/2026 | Site Zoning - Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-FBB-1125-00143 2469 N. Country Club Rd. Tucson, AZ 85716 Shipping Container (1st Review) TRANSMITTAL DATE: 1/5/2026 The site is zoned C-1 (UDC 4.7.20) Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: Please dimension the property lines as noted in the sample site plan: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example. 2. Comment: Please label the surrounding zoning classifications on your site plan since setbacks are measured differently for each zone: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example. 3. Comment: Please provide the height of the shipping container as setbacks in the C-1 zone for nonresidential use to a residential zone are measured at 1 ½ (Height of the proposed container exterior walls). 4. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 12/05/2025 | Fire New Construction - Standard | REVIEW COMPLETED | |||
| 12/02/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |