Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-FBB-0924-00165
Parcel: 12912192A

Review Status: Requires Resubmit

Review Details: MANUFACTURED/MOBILE/PARK MODEL HOME v.2

Permit Number - TC-FBB-0924-00165
Review Name: MANUFACTURED/MOBILE/PARK MODEL HOME v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/04/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/14/2024 Residential Building REQUIRES RESUBMIT Dwelling units require six foot clear space between structures when not one hour fire rated, R302.1 (City of Tucson Amended). Show how the existing building complies with the one hour rated construction listed at IBC Table 721.1(2) or provide a clear six foot space between dwellings.
11/04/2024 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Fernando Garcia
Planning & Development Services Department – Zoning Review Section

PROJECT: TD-DEV- – Residential Addition/Alteration
3556 S Clark Av, Tucson, AZ 85713
Building Plan Review (2nd Review)

TRANSMITTAL DATE: November 4, 2024

This site is located in an R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone subject to use-specific standards 4.9.7.B.6, .9 and .10.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised plans, as noted in the comment below, along with a detailed letter indicating responses to the review comments.

Alert me by email to fernando.garcia2@tucsonaz.gov upon resubmittal for faster review.

1. (COMMENT) Confirm dimensions for the existing building. The Pima County Assessor shows dimensions of 34’ x 36’. It, and overheard imagery, also show what appear an addition to the south-facing part of the existing home.

No permit was found for this addition. Either provide proof of permitting or submit for a permit using as-built plans.

Show this addition on plans and indicate its dimensions. Revise lot coverage calculations.

2. (COMMENT) In an R-2 zone, minimum side and rear setbacks are 6’ or 2/3 the height of the adjacent building wall height. As such, the minimum setback for the carport to the north is 6’ based on a height of 8’. 2’ is shown. A DDO is required to be approved prior to final Site Zoning approval of this permit.

3. (COMMENT) The minimum front street perimeter yard is 20’. For the carport, 5’ is shown. A DDO is required to be approved prior to final Site Zoning approval of this permit.

4. (COMMENT) The minimum street perimeter yard for a street other than the front street is 10’. For the gazebo, 7’ is shown. A DDO is required to be approved prior to final Site Zoning approval of this permit.

5. (COMMENT) Please see Residential Building comment about distance between proposed manufactured home and the existing home.

6. (COMMENT) Site Zoning recognizes that a DDO application has been submitted. Final Site Zoning approval of this permit is contingent upon approval of that DDO application first.

If you have any questions about this transmittal, please contact Fernando L. Garcia at fernando.garcia2@tucsonaz.gov.
10/14/2024 PDSD Application Completeness Express REVIEW COMPLETED