Permit Review Detail
Review Status: Requires Resubmit
Review Details: MANUFACTURED/MOBILE/PARK MODEL HOME v.1
Permit Number - TC-FBB-0826-00101
Review Name: MANUFACTURED/MOBILE/PARK MODEL HOME v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/14/2026 | Residential Building | APPROVED | |||
| 08/24/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/24/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit: TC-FBB-0826-00101 – Factory Built Home Location: 1325 W SILVERLAKE RD Unit 147 Review Date: 8/24/2026 This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-06 and Technical Manual (TM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage… Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-rete… Overall, for application submittal requirements, see Administrative Manual Section 2-06 Site Engineering: 1. This project is in a Regulated Flood Zone “AE” associated with the West Branch of the Santa Cruz River and will require a floodplain use permit and elevation certification for the lowest structural member of the new building determined from the regulatory Base Flood Elevation (BFE). a. For a proper determination of the regulatory BFE to determine the required finish elevation needed for the new structure, please submit an overall map of the mobile home community as either an aerial photo or site map with the project lot clearly labeled. 2. Once we have the information needed to determine the BFE, a Floodplain use permit will be created internally on behalf of the applicant to aid in the permitting process. 3. Site Engineering will be unable to approve permit TC-FBB-0826-00101 until the associated floodplain permit is approved and issued. If you have any questions or concerns, please contact Joe Macaulay at: Joe.Macaulay@tucsonaz.gov |
||
| 08/21/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston Planner PROJECT: TC-FBB-0826-00101 1325 W Silverlake Rd., Tucson, AZ 85713 Manufactured Home (1st Review) TRANSMITTAL DATE: 08/21/2026 This site is located in the MH-1 zone (UDC 4.7.10). A single-family residence is a permitted use in this zone (Table 4.8-2). RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. Please provide a reference/site map showing where in the manufactured home park the unit is to be located. 2. Provide dimensions between the manufactured home and awnings to their respective property lines. 3. Include the MH-1 zoning on the site plan. 4. Indicate whether the towing tongue will be removed. 5. Provide a response letter explaining how all staff comments have been addressed. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov . |
||
| 08/14/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |