Permit Review Detail
Review Status: Requires Resubmit
Review Details: SHIPPING CONTAINER v.1
Permit Number - TC-FBB-0724-00131
Review Name: SHIPPING CONTAINER v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/12/2024 | Site Engineering | NOT REQUIRED | |||
| 08/14/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/14/2024 | Residential Building | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter to address each of the comments indicating how the Building Review comments were addressed. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. 1. Please provide the Structural Calculations with your next submittal IBC 107.2.7 2. Please amend plans to include the site plan in the construction drawings, update the sheet index and ensure each sheet has a unique sheet label number. R106.1.1 3. Sheet T1.0: Please amend Code Review to add these applicable codes to the list. IRC R106.1.1 2018 IBC, 2017 NEC, 2012 City of Tucson/Pima County Outdoor Lighting Code, Local Amendments to Above Codes ( www.tucsonaz.gov/pdsd/building-codes ) Treat this as a typical note. 4. Sheet A.0: Please amend plans to show the size and connection of the new 4” house connection sewer to the existing house connection sewer to include cleanout locations. R106.1 5.Sheet A1.0: Please amend plans to dimension the egress window in the bedroom to show compliance wit R310. Specifically, the clear width, and clear height as well as the square footage of the clear opening. The provided window G appears to be too small. R106.1.1 4. Sheet A3.0: Please amend plans to provide the ESR# for the Sprayed Foam and the Polycarbonate insulation. Treat as a typical note for all items approved by testing labs. IRC R106.1.1 6. Sheet A3.0 Detail 2/3: Please amend plans sheets to indicate one layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or other approved water-resistive barrier shall be applied over studs or sheathing of all exterior walls. No.15 asphalt felt shall be applied horizontally, with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 mm). Other approved materials shall be installed in accordance with the water-resistive barrier manufacturer’s installation instructions. The No. 15 asphalt felt or other approved water-resistive barrier material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. R703.2 7. Sheet S0.0: Please provide structural sheets S0.0, S1.0, and S4.0 signed by the Engineer of. IRC 106.1.1 8. Sheet E0.0: Please amend plans to provide electrical load calculations for the existing 200A main panel to ensure it is sufficiently sized for both electrical loads. E3602.2 9. Sheet E0.0: Amend plans to note main bonding jumper to not be used in sub panel E3607.3.2 10.Sheet E0.0: Please amend plans as ground to incoming water does not appear to be possible, as metallic water piping is included on these plans. Please provide a grounding electrode system such as two ground rods per E3608.1.4 and E3608.3.4.1 and show on electrical riser diagram. IRC R106.1.1 11. Sheet E0.0, E1.0: Please amend plans to show the method of supplying power and grounding to the office building. R106.1.1 For example, show on equipment riser, show panel schedule etc. Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 08/07/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-FBB-0724-00131 201 W ADAMS ST. – R-2 Site built sleeping quarters and office from converted shipping containers (1st Review) TRANSMITTAL DATE: August 7, 2024 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. 1. Provide a lot coverage calculation that meets the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example, 2. Provide a setback dimension from the east end of the proposed Office to the east property line. 3. Provide a dimension from the centerline of 10th Ave to the face of curb and from the face of curb to the east property line. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 07/11/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |