Permit Review Detail
Review Status: Requires Resubmit
Review Details: SHIPPING CONTAINER v.2
Permit Number - TC-FBB-0724-00131
Review Name: SHIPPING CONTAINER v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/24/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/23/2024 | Residential Building | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter to address each of the comments indicating how the Building Review comments were addressed. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. 4. Sheet A.0: New comment: Please amend sewer from new sleeping quarters to be 3" in diameter as the sewer line cannot decrease in size in the direction of flow. IRC P3005.1.6 the sheet skows both 4” and 3” for the size, please remove the 4” reference. 5.Sheet A1.0: Please amend plans to dimension the egress window in the bedroom to show compliance with R310. Comment remains and is expanded: The Bedroom window is called out as 695 and we only see a 2’-0” dimension. It appears that for a single hung window a 3'-0"x5'-0" would be the smallest in that style suitable for an egress window. Providing the sill height, clear width, clear height and the net opening size of 5’-0” when used on the first floor. Please provide a code compliant window and include it in the window schedule. New comment from this review: Window G in the bathroom appears to be less than 60” above the walking surface and is required to use Tempered Glazing. IRC R308.4.5 Glazing and wet surfaces. Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 09/24/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-FBB-0724-00131 201 W ADAMS ST. – R-2 Site built sleeping quarters and office from converted shipping containers (2nd Review) TRANSMITTAL DATE: September 24, 2024 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. 1. The 7’-5” perimeter yard setback shown from the east end of the proposed office to the east property line does not meet the required 10’ side street perimeter yard setback, UDC Article 6.4.5.C.1.b. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 08/26/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |