Permit Review Detail
Review Status: Requires Resubmit
Review Details: SHIPPING CONTAINER v.1
Permit Number - TC-FBB-0524-00066
Review Name: SHIPPING CONTAINER v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/14/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/14/2024 | Residential Building | REQUIRES RESUBMIT | Please submit your revised documents along with a detailed response letter, which states how all Building Review Section comments were addressed. Plans were incomplete and further comments might arise after these comments are addressed. Sheet T1.0: Please update the Design loading to remove the reference to Mueller and amend Live load to show use as an occupied deck. Sheet to be stamped by Engineer of Record IRC 106.1 Sheet A0.0: Please amend plans to provide dimensions to indicate the size of the structure. IRC 106.1 Sheet A1.0: Please amend plans to show guard height, pocket spacing, and attachment details. IRC 106.2 Sheet A1.0: Amend plans to provide the following information for the spiral stairway. IRC 106.1 a. Foundation drawing, design and calculations prepared by Az licensed registrant. IBC 107.2.1 b. Stairway drawing, design and calculations prepared by Az licensed registrant. IBC 107.2.1 c. Guard drawing, design and calculations to include connections, prepared by Az licensed registrant. IBC 107.2.1 Sheet A1.0: Amend plans to show architectural drawing of spiral stairs to show compliance with R311.7.10.1 Spiral stairways. Sheet A1.0: Amend plans to provide illumination as stairways shall be provided with illumination in accordance with R311.7.9. Exterior stairways shall be provided with an artificial light source located at the top landing of the stairway. IRC R303.8. Sheet A1.0: Amend plans to provide a statement of special inspections. IBC 1704.1 Sheet A1.0: Amend plans to provide safety glazing at all hazardous locations. IRC R308.4 Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 06/05/2024 | Site Engineering | REQUIRES RESUBMIT | This project is within a regulated floodplain and requires a Floodplain Use Permit (FUP.) Please start a new FUP at our permit application web page: https://tdc-online.tucsonaz.gov/#/home NOTE: Construction of new buildings require elevation one foot above the base flood elevation, which may require that the foundation of the building be raised as much as two feet above the existing elevation onsite. Storage buildings with no utilities may be wet floodproofed using flood vents. For all new construction buildings, two elevation certificates must be filled out by a registered land surveyor and submitted to the City, one before the foundation is poured and one after construction is completed. Instructions: 1. Navigate into the current project in the “My Work” tab. Within the permit, navigate to the “Sub-Records” tab and click “Apply” on the Floodplain Use Permit Sub-Record 2. Locations -> Confirm the location is accurate to the project. Click “Next” 3. Type -> Fill in the “Square Feet” and “Valuation” boxes with the project area and a contractor-provided cost estimate (See note above: for new structures, input 0). Click “Next” 4. Contacts -> Confirm contacts and add any additional contacts if applicable. Click “Next” 5. More Info -> This will be filled in by the engineer assigned to your case, Click “Next” 6. Attachments -> Please attach the project plan, supporting documentation for the cost estimate (if applicable), and a drainage/hydrology report (if applicable). Click “Next” 7. Signature -> Read the statement and type your name. Sign your name below (You may Enable Type Signature to have the software sign for you.) Click “Next” 8. Review and Submit -> Review all information to ensure accuracy. Click “Submit” Contact Lianne Evans at lianne.evans@tucsonaz.gov if you have any questions about the FUP. |
||
| 06/04/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-FBB-0524-00066 3336 E SENECA ST. – R-1 Converted shipping container for storage (1st Review) TRANSMITTAL DATE: June 4, 2024 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9. 1. The lot coverage calculation is not correct. Per UDC Article 6.4.3.C.1.a Roofed areas, porches, open on at least one side are not included in the calculation. Also it does not appear that the storage container is included in the lot coverage and should be. 2. Provide the zoning for all adjacent properties on the plot plan. The UDC can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 05/09/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |