Permit Number: TC-FBB-0326-00039
Parcel: 113111010

Review Status: Requires Resubmit

Review Details: PERMANENT MODULAR v.1

Permit Number - TC-FBB-0326-00039
Review Name: PERMANENT MODULAR v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/04/2026 Commercial Electrical - Standard APPROVED
04/23/2026 Site Engineering - Standard APPROVED
05/04/2026 Commercial Plumbing - Standard NOT REQUIRED
04/20/2026 Site Zoning - Standard NOT REQUIRED TUSD is exempt from Site Zoning review per communication w/ LShamis.
05/06/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/24/2026 Commercial Building - Standard REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov
1. The modular building plans are required to be approved and stamped by the State of Arizona ADOH prior to the building permit approval. IBC 107.2.1
2. A copy of the ADOH installation permit will be required prior to permit issuance. IBC 107.2.1
3. Please update the governing codes to the following:
2024 International Building Code (IBC)
2017 ICC A117.1 Accessibility Code (by reference)
2024 International Mechanical Code (IMC)
2024 International Plumbing Code (IPC)
2023 National Electrical Code (NEC)
2024 International Fire Code (IFC)
2018 International Energy Conservation Code (IECC)
City of Tucson/Pima County Outdoor Lighting Code
Local Amendments to Above Codes ( www.tucsonaz.gov/pdsd/building-codes )
Please contact me if you have any questions about the above comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
05/06/2026 Fire New Construction - Standard REQUIRES RESUBMIT Resolve building review comments.
Questions: patricia.shelton@tucsonaz.gov
05/04/2026 Outdoor Lighting - Standard REQUIRES RESUBMIT Outdoor Lighting Review TC-FBB-0326-00039 (1701 E SENECA ST Unit:BLDG 6 TUCSON, AZ 85719)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov

Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).
Outdoor Lighting Review:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf


1. The replacement, relocation and installation of new lighting fixtures requires compliance with the City of Tucson Outdoor Lighting Code. 4 new lighting fixtures added.
2. Provide an outdoor site lighting plan that meets the requirements of OLC 104.2. Show/locate the different light sources on your site plan, both new and existing. Number the light fixtures on your lighting fixture table and use the same number on your site plan.
3. List the Lighting Area per OLC (typically E3) chapter 3 and used in Table 401.1. Specify the compliance option from Table 401.1 that is being used. Total outdoor light output shall not exceed the lumen limits listed in Table 401.1.
4. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 104.2.1, 401.2. Include all exterior fixtures on the property in the calculations. List shielded and unshielded lights in the calculation.
5. Show unshielded fixtures with a maximum of 3,000 lumens, OLC 401.4.
6. Show lamps with a maximum of 3500K color temperature, OLC 402.1.
7. Provide the manufacturer’s specification sheets for the outdoor lighting fixtures. Include the lumen and color temperature values for each outdoor fixture type.
8. Indicate whether or not a special inspection is required per sec. 104.2.2, and 106.2.

https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate_odl.pdf

9. Specify any exceptions used.

10. Provide Curfew lighting controls If applicable Per section 403.
03/25/2026 PDSD Application Completeness Express REVIEW COMPLETED