Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-FBB-0326-00034
Parcel: 11623118C

Review Status: Requires Resubmit

Review Details: MANUFACTURED/MOBILE/PARK MODEL HOME v.1

Permit Number - TC-FBB-0326-00034
Review Name: MANUFACTURED/MOBILE/PARK MODEL HOME v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/23/2026 Residential Building APPROVED
03/27/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/27/2026 Residential Engineering REQUIRES RESUBMIT Permit: TC-FBB-0326-00034 – Factory Built Home
Location: 1022 S KROEGER LN
Review Date: 3/27/2026

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-06 and Technical Manual (TM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code.

Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage…

Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-rete…

Overall, for application submittal requirements, see Administrative Manual Section 2-06

Site Engineering:
1. Per the City of Tucson Inclusive Home Design Ordinance https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf, all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway (or apron), sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in 2017 ICC A117.1 Sections 402-403, including the minimum 4ft-width, slope and composition materials.
2. If by virtue of terrain or other unusual characteristics of the building site, there are practical difficulties associated with compliance, a request to waive this requirement may be submitted through Tucson Development Center Online. Select “Building Official Appeal” from the “Sub-Records” tab of this permit to apply.

If you have any questions or concerns, please contact Joe Macaulay at: Joe.Macaulay@tucsonaz.gov
03/23/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Jeffrey W. Cassidy, Planner
Planning & Development Services Department – Current Zoning Review Section

PROJECT: TC-FBB-0326-00034 – Residential Building – Installation of a New 28X56 Manufactured home
1022 S KROEGER LN TUCSON, AZ 85745 (R-2 Zoning)
Site Plan Review – 1st Review

TRANSMITTAL DATE: March 23, 2026

This site is in the R-2 Residence Zone (UDC 4.7.9). Manufactured housing is permitted in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

The City's Unified Development Code (UDC) (Section 1.4.1.C) establishes that before the City issues any approvals or permits; we must confirm that a site complies with UDC standards. Therefore, as part of permit reviews, we review a site's permit history and compare it to aerial photography to confirm that unpermitted work has not occurred. In many cases, this does mean that a homeowner must apply for permits for unpermitted work before we can approve any new work on that site.

Plan review for the above referenced manufactured housing has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

1. COMMENT: The access into the site, per the drawing is indicated to be at the northwest corner of the property onto and through parcel 11623101A. Draw, label and dimension recorded sequence number for the 21’-0” dedicated easement to make it clear where the vehicle and utility access is coming from.

2. COMMENT:

A. As part of the passing of Ordinance 12219 this past December of 2025, the following landscaping is required for all new single family residential, middle housing development, and accessory dwelling units, as of January 01, 2026, per UDC 7.6.10.

1. One tree / 1,000 floor area.

2. A 5’-0” wide strip of vegetative groundcover is required within the front yard setback per the calculation below (minus the sections that have a driveway and/or pedestrian sidewalk (from the street sidewalk to the units’ front entrance). Parcels with less than 30 lineal feet of street frontage may place the required ground cover in alternate locations indicated on the site plan.

(X Linear feet of Street Frontage) – (Y curb cut width) x (5 Foot Depth) = Z Square Feet of required vegetative groundcover.

3. Plants must be low to very low water use with a hardiness rating of 15 degrees Fahrenheit or lower and non-invasive. Options are listed in Section 5-02.5.0 of the Technical Standards Manual. Exceptions to these criteria or plants that are not listed in Section 5-02.5.0 of the Technical Standards Manual, may be approved by the PDSD Landscape Architect.

B. Required landscaping must be located as follows:

1. A minimum of fifty percent of the required canopy trees must be located within the front yard setback area.

i. Exception: If site constraints prevent new tree placement in a front yard, five shrubs may be substituted per required tree. Required trees must still be placed elsewhere on the site. Shrubs used as a substitute plant material for the required tree shall range from three feet in height by three feet in width, or larger. Shrubs must follow the relevant spacings from utility lines in section 5 01.5.11of the Technical Standards Manual but can be planted one radius of their mature width from foundations, enclosed sidewalks, sidewalks, and curbs.

ii. Exception: The tree required for an accessory dwelling unit may be placed anywhere on site.

2. Trees may be planted at varying distances apart.

3. Required landscaping is not restricted to the first 10 feet onto the property from the existing or future right-of-way line.

4. Newly planted trees must be placed at a minimum distance from existing or proposed City of Tucson-owned or private utility-owned lines, as found in section 5-01.5.11 of the Technical Standards Manual. Tree plantings are not permitted in El Paso Gas Easements or under overhead power lines.

5. Trees shall be placed a minimum of ten feet from the center of the tree trunk to any enclosed structure.

6. Trees shall be placed a minimum of five feet from the back of the sidewalk or curb. If this standard cannot be met, then root barriers are required and must be illustrated on the submitted construction plans.

7. Trees must be planted in a six-to-nine-inch depressed planting area of at least 50 square feet (four-foot radius, or alternatives as proposed) and at least ten feet away from a building foundation.

8. Existing, established trees on property, at least 4 inches trunk diameter at chest height, located at least ten feet from the foundation or with an unobstructed dripline at maturity, shall count toward this requirement. The root systems of existing trees used for this requirement must be protected from soil compaction during construction using perimeter protective fencing around the dripline. Established trees are not required to have a depressed planting area. Existing shrubs and vegetative groundcovers may also be used toward the required landscaping.

C. Vegetation shall be established, maintained, and sustained throughout its life in support of the City’s tree count, climate, and walkability goals. One of the following two options may be used:

1. Drip or bubbler irrigation with backflow protection. A simple irrigation system can be part of the domestic water supply for the residence.

2. Alternate methods, such as rainwater harvesting, hand watering, and greywater systems, as proposed by the property owner and approved by the PDSD Landscape Architect.

3. COMMENT: The site plan provided is incomplete.

Provide a site plan that meets the requirements show in the plot plan example at the following link:

https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/plan-samples/full-site-plan_feb2026.pdf

Specifically:

A. Provide accurate property line lengths to be reflective of information on Pima County’s website. Refer to Pima County’s website https://www.asr.pima.gov/ParcelData/Map/Arm/T14S/M14131444.PDF . The math of the property line lengths will produce the total parcel square footage. Be aware that some easements may require referring to the title report of the property (procure at title company if not already in possession.

B. A lot coverage calculation table was not provided. Per UDC Article 6.4.3.C.1.a roofed areas, porches, open on at least one side are NOT included in the calculation and per UDC Article 6.4.3.B.3.b Vehicular use areas, measured within the outside edges of any area allocated to vehicle use, whether improved or unimproved, are included in the lot coverage.

Calculate (measure) square footage of every enclosed (NOT open structures like a porch, ramada, carport) structure on site and all vehicular use area (driveway, parking, turnaround, backup) and input into lot coverage calculation table. A carport would be calculated under vehicular use area. These separate ‘category numbers are added together and divided by the total parcel square footage to produce the lot coverage percentage that demonstrates compliance (or not).

C. The setbacks for the north, south and west property lines is 5’-0” while the front yard setback is 20’-0” (to S Kroeger Ln).

D. There are inconsistencies through the set as to the size of the proposed manufactured home. Update labels through set that need to be updated to desired size.

E. Provide the missing site plan scale, corresponding graphic scale and north arrow.

4. COMMENT: Per UDC Table 7.4.4-1 and under the Residential Use Group and Single-Family Dwellings, 2 spaces per dwelling unit plus visitor parking required at a ratio of 0.25 space per unit. Draw, label and dimension the required parking stalls.

5. COMMENT: Per UDC 6.6.3.C. standard, detached accessory buildings, including accessory dwelling units, are not permitted in the buildable area extending the full width of the lot between the principal building and front street lot line, except for shade structures or carports not over 400 square feet in floor area, terraces and steps not over three high above the natural grade, paved areas, and fences or walls. Regarding the existing residence, there appear to be multiple structures directly east of the residence.

Three options exist:

A. Move all structures to the west of the residence.

B. Remove all the structures to the east of the residence.

C. Leave the design as-is and attempt to secure relief from this standard through the Design Development Option (DDO) process.

Be aware this is an extra 6-week review and the neighbors within 100’-0” are made aware of this attempt to seek relief from being in the setback. Zoning will not be able to approve the permit application until the DDO is approved. This information is linked here:

https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration#section-3

To submit a DDO application, apply for a new sub-record under this permit at TDC Online.

https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf

See below for more information on the DDO process.

6. COMMENT: Per UDC Article 6.6.3.D; Accessory structures, except for accessory dwelling units, shall not exceed 12 feet in height, unless attached to a principal structure. If attached to the principal structure, maximum height permitted shall be the same as for the principal structure.

Based on provided information the structures to the east of the existing residence appear to exceed the allowed 12’ height. Provide heights of all structures. If they exceed this standard, a Board of Adjustment for Variance will be required to permit the shade structure as shown on the plan. See variance requirements below. An option would be to connect the shade structure to the existing residence with a 5’ wide roof structure that can support a 20-pound live load.

Zoning cannot approve this permit until the Board of Adjustment (B/A) Variance Process is completed and approved.

See below for more information on the B/A Variance process.

7. COMMENT: After reviewing the property documentation history in Property Research Online (PRO), zoning could not verify any permit documentation for the existing structures.

7a. The existing residence.
7b. The structure to the west of the residence.
7c. The three structures to the east of the residence.

Zoning will not be able to approve the permit application until the permit information is provided. If permit documentation cannot be provided, submit a separate permit for all the existing structures.

Per TABLE 6.3-2.A of the UDC (referenced below), the perimeter yard setback(s) along the north and east property line(s) are 5’-0”. Depending on how far the existing structures sit off the property lines, there are five options:

A. Move the structures out of the setback(s)

B. Remove the strcutures.

C. Distance is 1’-0” or more or 1-0” OR Less (encroaching in setback):
For the structures that are unhabitable, attempt to secure a neighbor setback waiver:

(Neighbor Waiver Sample – COPY AND PASTE ALL WAIVERS ONTO SITE PLAN EXACTLY AS SHOWN BELOW):

My Name is __________________ and I am the owner of the property located at
________________________. I have reviewed the site plan, and I have no objection to structure being located or constructed ______ feet from the property line as depicted on the site plan.

Signature: _______________________ Date:___________________________

Mi hombre es ________________ y yo soy el dueño de la propiedad ubicada en la _____________________. He revisado el plan y no tengo ninguna objeción a que estructura se encuentra o construye ____________ desde la línea de propiedad, como se muestra en el plan.

Firma: _________________________Fecha:__________________________

D. Distance is 1’-0” or more from property line AND unable to obtain neighbor waiver: If unsuccessful in the attempt to retrieve the neighbor waiver, there is a Design Development Option (or DDO) which affords an attempt to seek relief from the setback requirements.

Know this is an extra 6-week review and the neighbors within 100’-0” are made aware of this attempt to seek relief from being in the setback. Zoning will not be able to approve the permit application until the DDO is approved. This information is linked here:

https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration#section-3

To submit a DDO application, apply for a new sub-record under this permit at TDC Online. Alert the zoning review you intend to pursue so they can create the sub-record for you ahead of your next submittal Jeffrey.cassidy@tucsonaz.gov

https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf

See below for more information on the DDO process.

E. Distance is less than 1’-0” from property line AND unable to obtain neighbor waiver:
If unsuccessful in your attempt to retrieve the neighbor waiver, a board of adjustment variance will be required to permit the structure as shown on the site. See variance requirements below. Zoning cannot approve this permit until the Board of Adjustment (B/A) Variance Process is completed and approved.

See below for more information on the B/A Variance process.

8. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments.

Board of Adjustment application/requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration .
Contact for the Board of Adjustment is Mark Castro at Mark.Castro@tucsonaz.gov

DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration . Note that multiple DDO’s can be submitted concurrently on the same application.

To submit a DDO application, apply for a new sub-record under this permit at TDC Online. In order to get this specific review scheduled and if you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. Zoning cannot approve the zoning review portion of the permit until the DDO has been approved.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:

1. Corrected building permit

2. Provide a detailed response letter (clarification narrative) with your submittal that clearly shows how you have addressed all Zoning comments.

3. Resubmit ALL documents associated with this permit (all drawings in sheet index)

To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home

Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf

If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code
03/13/2026 PDSD Application Completeness Express REVIEW COMPLETED